X-Radiation - Panasonic TC-14Z88RQ Service Manual

Table of Contents

Advertisement

http://202.224.189.179/viewing/OT/TC-14Z88RQ/SVC/s0104000000.html

1.4 X-Radiation

TOP PREVIOUS NEXT
Warning:
The potential sources of X-Radiation in TV set are the EHT section and the picture tube. When using a
picture tube test jig for service, ensure that jig is capable of handling
Radiation.
Note:
It is important to use an accurate periodically calibrated high voltage meter.
1. Set the brightness to minimum.
2. Use the remocon to get into Service Mode.
3. Measure the EHT. The meter reading should indicate
of tolerance, immediate service and correction is required to prevent the possibility of premature
component failure.
4. To prevent the possibility X-Radiation, it is essential to use the specified picture tube, if service
replacement becomes necessary.
TOP PREVIOUS NEXT
http://202.224.189.179/viewing/OT/TC-14Z88RQ/SVC/s0104000000.html10.02.2006 2:28:46
26.0kV
without causing X-
24.5±-1.5kV
. If the meter indication is out

Hide quick links: