Marine diesel generating set 230v / 50hz masterbus controlled
Hide thumbs Also See for M-SC3.5:
Table of Contents

Advertisement

2 INFORMATION

2.1

SAFETY

2.1.1

General

When
correctly
installed
circumstances this generating set fulfils EC safety
regulations. This generating set could be part of an
installation or could be used in a way that additional
regulations of the EC or other authorities have to be taken
into account.
Circumstances could make it also necessary
to take additional measures. Be aware of wet
conditions
and
caused by explosive gases etc.
2.1.2

Electrical safety

The voltage of 230 Volt generated by this
generating set is dangerous and if instructions
and procedures are not strictly observed may
result in electrical shock which will result in
severe personal injury or loss of life.
Check all wiring at least once a year. Defects,
such as loose connections, burned cables etc.
must be repaired immediately.
Do not work on the electrical system if it is still
connected to a current source. Only allow
changes in your electrical system to be carried
out by qualified electricians.
Connection and protection must be done in
accordance with local standards.
Using event based commands the generator can
start
unexpectedly.
electrical system, the 30 Amp fuse must be
removed from the Digital Diesel Control panel
and the battery plus cable must be removed from
the battery.
Warning signs indicate parts which could be
live.
2.1.3

Earth insulation failures

According to local regulations and depending on the
application it could be necessary to take measures for
protection against earth insulation failures.
In the standard delivery "neutral" and "ground" are not
connected. To make a connection between "neutral" and
"ground" could be necessary as part of a specific
insulation failure protection system.
EN / M-SC3.5 / May 2010
and
used
in
normal
hazardous
environments
When
working
on
the
Small pleasure craft in Europe is submitted to The
Recreational Craft Directive 94/25/EC. The guidelines of
this directive refer to (ISO 13297).
When the installation complies with this standard the
"neutral" and "ground" should be connected on the
generating set. (Refer to the electrical diagram, page 15).
In all situations the transfer switches between
shore, inverter and generator should switch
both neutral and L1. Of course this is the case
when using a Masterswitch.
Be aware that insulation protection systems can be
different for different applications and even within the ship
there could be different standards for different spaces. We
did refer to the Recreational Craft Directive that applies to
pleasure craft up to 24 m of length. Sometimes one has to
comply with other standards such as the rules of
certification societies like Lloyds Register of Shipping or
Veritas, regulations for the protection of personal, building
legislation, etc. It is of the greatest importance to have
expert advice on this issue.
2.1.4

Installation

Whisper generating sets are not self contained and have
to be properly installed in enclosed areas such as a
machine room.
Installation includes measures to be taken to
outlet exhaust fumes which contain carbon
monoxide and are extremely dangerous.
Carbon
monoxide
odourless gas. Inhalation produces headache,
nausea
or
measures for proper ventilation, safe electric
connections, safe installation of the starting
battery, proper fitting of the cooling system
and fuel pipes etc. Refer to the installation
manual.
2.1.5

Operation

The M-SC3.5 generating set does not have any external
moving parts like fans and V-belts and therefore is very
safe.
Nevertheless take note of the signs on the
generating set which show symbols in a
triangle indicating danger.
INFORMATION
(CO)
is
an
invisible
death.
Installation