No Steam Pre-Heat - Alto-Shaam 10.10ES Technical & Service Manual

Combitherm electric series
Hide thumbs Also See for 10.10ES:
Table of Contents

Advertisement

T R O U B L E S H O O T I N G T R E E S
E S — N o S t e a m P r e - H e a t
See "No Generator Fill".
Test for coil voltage at contactors.
If K-1/K-2
K-1-A-1 is L-1 switched from X-1 pin 2 on the relay board.
K-1-A-2 is L-2 constantly supplied from the 130 terminal.
K-2-A-1 is L-1 switched from X-1 pin 6 on the relay board.
K-2-A-2 is L-2 constantly supplied from K-1-A-2.
If K-1/2/3
K-1-A-1 is L-1 switched from X-1 pin 2 on the relay board.
K-1-A-2 is L-2 constantly supplied from the 130 terminal.
K-2-A-1 is L-1 fed from K-1-A-1.
K-2-A-2 is L-2 from K-41-A-2.
K-3-A-1 is L-1 switched from X-1 pin 6 on the relay board.
K-3-A-2 is L-2 constantly supplied from K-1-A-2.
T
Is the generator full and
the B-1/B-2 satisfied?
No
Test for a faulty probe. If
not faulty, pre-heat it.
Replace faulty contactor(s).
Repair wiring issue.
Replace faulty element(s).
Test for faulty probe or scaled tank.
T
• C
r o u b l e s h o o T i n g
r e e s
Yes
Is the B-4 probe below set
point (88°C/190°F)?
No
Replace faulty contactor(s).
Check for wiring issue
between K-1/2/3, L-1/2/3
and main terminal block.
No
Are all element loops
drawing power?
No
No
Preheat is complete.
e
t
o m b i t h e r m
l e C t r i C
e C h n i C a l
Yes
Are the K-1/2/3 contactors
being energized?
No
Yes
Are the K-1/2/3 contactors
pulling in?
No
Yes
Is there voltage across the
L-1/2/3 side of K-1/2/3?
No
Yes
Is there voltage across
T-1/2/3 on K-1/2/3?
No
Yes
Is there voltage at the
element loop connections?
Yes
Yes
After 3-4 minutes of
heating is B-4 satisfied?
Yes
S
m
• D - 6
e r v i C e
a n u a l