Electrical Work - Toshiba RAS-10SA-E-1 Service Manual

Air conditioner split wall type
Table of Contents

Advertisement

<When the installation plate is directly mounted
on the wall>
(1) Securely fit the installation plate onto the wall by
screwing it in the upper and lower parts to hook
up the indoor unit.
(2) Install the installation plate horizontally in the wall.
(3) To mount the installation plate on a concrete wall
with anchor bolts, utilize the anchor bolt holes as
shown in the above figure.
CAUTION
When installing the installation plate with mounting
screw, do not use the anchor bolt hole. Otherwise
the unit may fall down and result in personal injury
and property damage.
Anchor bolt
Projection
15mm
or less
5mm dia, hole
3 Clip anchor
8 Mounting screw ø4 x 25
Fig. 8-4-4
CAUTION
Failure to firmly install the unit may result in
personal injury and property damage if the unit
falls.
• In case of block, brick, concrete or similar type walls,
make 5 mm dia, holes in the wall.
• Inser t
clip anchors for appropriate
3
mounting screws.
NOTE :
• Install the installation plate using 4 to 6 pieces of
mounting screw securing four corners with screws.
Installation plate
(Keep horizontal direction)

8-4-2. Electrical Work

(1) The supply voltage must be the same as the rated
voltage of the air conditioner.
(2) Prepare the power source for exclusive use with
the air conditioner.
Model
Power source
Maximum
running current
Plug socket &
fuse rating
Wiring
* No adjustment is necessary.
CAUTION
• Use power specified in above table.
• This appliance can be connected to the mains
in either of the following two ways.
(1) Connecting the power cord to the main power
supply provided with a circuit breaker or switch
with a contact of 3 mm or more.
In this case, an approved circuit breaker or
switch must be used.
(2) Attaching a plug to the power cord and pluging
it in to the wall outlet.
In this case, an approved power cord and plug
must be used.
NOTE :
• Perform wiring works so as to allow a generous
wiring capacity.
8
– 23 –
RAS-10SK-E/10SA-E, 10SA-E-1
RAS-10SKX/10SAX, 10SAX-1
50Hz *220/230/240V~ Single-phase
7.5 A
16 A
1mm
2
or more