Basic Programming Quick Reference Guide

1. Plug in the system
2. The display will alternate between Time and Flush Volume (Default 100 gallons)
3. Set the time to 12:01 PM by moving the Set Up button and/or the Set Down button
4. Press and hold the Program button to for 5 seconds to enter the programming menu
5. Once in the programming menu, continue to press the Program button to toggle through the various settings listed below
6. Use the Set Up button and/or the Set Down button to adjust the setting as desired
* In typical applications, only the Flush Duration, Flush Volume, and Time of Day would need adjustment
During cold weather, it is recommended that the installer warm the system up to room temperature before operating.
A 9V alkaline battery is recommended to be installed at all times for proper controller operation. The system will indicate when the
battery needs to be replaced by turning on the Low Battery LED.
1--- 0.5
Fr --- .0
d --- 0
E ---0
Pd ---0
y --- OFF
r --- OFF
n --- OFF
A --- 1
b --- 100
u --- 1
7 --- 2
F --- 6
F - 6 - 80.0
PL --- OFF
Page 22
Basic Programming Quick Reference Guide
Default Settings
Flush Duration- minutes (eg. 30 seconds = 0.5) (default 0.5 minutes)
Flow rate
Days since last regeneration
Prior volume used
Previous day usage
Time Aux off
Cancel setting
Chem pump off
Time override - days (default 1 day)
Flush volume - gallons (default 100 gallons)
US gallons
Meter immediate flush
Allows for pulse setting of flow meter
80 pulses per gallon
Lock OFF