Pentek FreshPoint U440 Service Manual page 15

Table of Contents

Advertisement

Meter/Solenoid Electrical Connection (Refer to Figure 5)
1.
Connect the drain solenoid wire harness to the solenoid valve.
2.
Insert the flow meter cable into the socket on the flow meter
3.
If installing with the backflush kit:
a. Remove the two transformer leads from the terminal strip (terminals 4 and 5) and replace them with the leads
from the higher-rated transformer provided in the kit.
b. Install inlet solenoid's wiring harness (backflush kit) to the control board. The inlet solenoid leads should be
installed in the same terminal locations as the drain solenoid (1-green, 2-black, 3-white). DO NOT connect the
wiring harness to the solenoid at this time.
4.
Plug the power cord transformer into a 120V GFI outlet.
Figure 5: Meter/Solenoid Electrical Connection Diagram
24 VAC Transformer
B
Solenoid Harness
Installation Instructions
T
B
1
6
Black
5
Black
White
4
White
3
White
Wt/Blk
2
Black
Yellow
Green
1
42209_REVB
Page 15