System Setup - Allpro ScanX-12 DVM Instruction Manual

Digital imaging system in-line erase
Table of Contents

Advertisement

SYSTEM SETUP

Authorized Imaging Software, such as Visix or VetRay, supplied by the dealer or other
Note:
company, must be installed on the computer in order to operate the ScanX.
ScanX Drivers and Utilities Installation
Before connecting the ScanX to your computer or attempting to use it for the first
time, run the Setup program on the ScanX Drivers and Utilities Disk included with
the ScanX. Normally, this program runs automatically when the CD is inserted
into the drive for the first time. If not, run the Setup program located in the root
directory of the CD (typically D:\Autorun.exe).
The Setup program guides you through updating the library files on your
computer, which must be completed before the ScanX will operate properly.
More information can be found in the Installation Instructions and Notes file
on the ScanX Drivers and Utilities Disk included with the ScanX.
ScanX Connection Procedure
Refer to Figure 1 and perform the following procedure to connect the ScanX for
operation for the first time.
1. Select a location that meets the SITE SELECTION guidelines.
2. Set up the computer according to the manufacturer's recommendations.
Make sure that the computer meets all requirements listed on page 10.
3. Verify that an authorized Imaging Software is installed properly on the
computer.
4. Verify that the supplied ScanX Drivers and Utilities Disk which contains the
USB drivers was properly installed per instructions above.
5. Connect the high speed USB cable between the USB Type B connector
located on the ScanX rear panel and the USB Type A connector located
on the computer.
Connect the 24V Power Supply Adapter to the ScanX prior to plugging the line cord into
Note:
the Mains outlet.
6. Connect the 24V Power Supply Adapter Output Connection Cable to the
ScanX DC Power Input Jack.
7. Connect the line cord between the Mains outlet and the 24V Power Supply
Adapter.
8. Switch the scanner from standby to ON by pressing the membrane READY
switch (
Verify that both the green and blue LED indicators above the READY and
ERASER switches illuminate.
9. With both the ScanX and computer turned on, Windows detects the ScanX
as a new USB Device. Windows should automatically find the drivers
installed from the ScanX Drivers and Utilities Disk.
) located on the Keypad Control Panel on the top of the scanner.
14

Advertisement

Table of Contents
loading

This manual is also suitable for:

Scanx dvm

Table of Contents