Page 1
SERVICE AND PARTS MANUAL MODEL 200 TIME RECORDERS ACROPRINT TIME RECORDER REV C – 00733 06–0116 5640 DEPARTURE DRIVE 07/97 RALEIGH, NC 27616 919–872–5800...
SERVICE AND PARTS MANUAL TABLE OF CONTENTS MOTOR AND DRIVE ASSEMBLY TYPEHEAD ASSEMBLY III. TYPEWHEEL ALIGNMENT A. REMOVING TYPEHEAD ASSEMBLY B. DISMANTLING TYPEHEAD ASSEMBLY C. REASSEMBLING TYPEHEAD CARD RECEIVER RIBBON DRIVE & REVERSE VII. PLATEN INSTALLATION AND TRIMMING VIII. ELECTRICAL INFORMATION SERVICE TIPS RECTIFIER TESTS SUGGESTED TOOLS &...
The Hour Typewheel Arbor extends through the Typehead every two years. However, if the Model 200 is installed in a Rear Plate to which the 24-Tooth Ratchet is set. With the Hour...
It will be necessary to periodically clean the Typewheel C. REASSEMBLING TYPEHEAD printing surfaces. DO NOT USE A SOLVENT cleaner, as most solvents will eventually tend to “gum-up” the Typewheel Put one drop of oil on Day-Date Wheel Shaft where it fits Assembly.
Springs to Typehead Rear Plate and install fourth Spacer. Upper Card Receiver to Inside Card Receiver and tighten the Install Spacer Washer on Detent Stud and Day-Date Detent four Mounting Screws. Plug in the Recorder and print on a Pawl; secure with E-clip. Detent Pawl should be free on card.
Both Microswitches must close before a print can be made. Once a print has been made and the time card is Every time the Model 200 prints, the Hammer Shaft pulls the still in the Card Receiver, the blade on the Cancellation Ribbon Feed Lever down.
Reversing Flange and the Reversing Shaft. This is how the Wheel can be rotated by the Hour Follower Level. Ribbon reverses. This will account for one (1) minute fast. Then the recorder will take on (1) normal minute. VII.PLATEN INSTALLATION AND TRIMMING C.
X. RECTIFIER TEST C. Activate System: Meter should read as follows: For AC For DC A. Preliminary Information Input Output voltage 1. Terminal Configuration and Schematic Diagram. Voltage Min. Max. 2. Types of Failures — Two types of Rectifier failures could 110-125vac 85vdc 12vdc...
d: With circuit activated, meter should read as follows: Output Voltage Minimum Maximum 8.5vdc 14.5 vdc If meter indicated with the acceptable maximum/minimum range, the rectifier is operating properly. XI. SUGGESTED TOOLS & EQUIPMENT 1/4" x 5/16" Open End Wrench 11/32"...
Page 10
150, P150 & 200 2-WIRE MINUTE 150, P150 & 200 2-WIRE REVERSE IMPLUSE NON CORRECTIVE POLARITY WITH CORRECTION 150, P150 & 200 3-WIRE MINUTE IMPULSE WITH CORRECTION...
Page 11
150, P150 & 200 WITH SIGNAL CONTROL OPTION (120/240V AC) 150 & P150 ONLY 150, P150 & 200 RECHARGEABLE WITH STANDARD MOV (120/240V AC)
Page 17
DEL 200 5 WHEEL TYPEHEAD ASSEMBLY (COMPLETE) PART NO. DESCRIPTION 20–0154–XXX TYPEHEAD ASSEMBLY (CONSULT FACTORY FOR PART NO.S) CODE TOTAL CODE TOTAL PART NO. DESCRIPTION QTY. REQ. PART NO. DESCRIPTION QTY. REQ. 31–0223–003 TYPEHEAD REAR PLATE 38–0105–002 HOUR FOLLOWER LEVER 37–0100–002...
Page 18
MODEL 200 TYPEHEAD & DIAL DRIVE ASSEMBLIES (Including Minute Impulse and Rechargeable Options)
Page 19
MODEL 200 TYPEHEAD & DIAL DRIVE ASSEMBLIES (Including Minute Impulse, and Rechargeable Options) CODE TOTAL CODE TOTAL PART NO. DESCRIPTION QTY. REQ. PART NO. DESCRIPTION QTY. REQ. 20–0154–XXX ASSEMBLED CLOCK TYPEHEAD 33–0101–002 MINUTE DETENT STUD 38–0129–000 DAY-DATE EXTENSION LEVER 32–0139–003 DIAL DRIVE GEAR 45–0100–002...
Page 21
MODEL 200 SIDE FRAME ASSEMBLY PART NO. DESCRIPTION 20–0196–XXX SIDE FRAME ASSEMBLY (COMPLETE) CODE TOTAL CODE TOTAL PART NO. DESCRIPTION QTY. REQ. PART NO. DESCRIPTION QTY. REQ. 47–0108–003 6-32 X 3/8" SLOTTED SCREW 31–0136–003 LEFT SIDE PLATE 33–0144–002 RIBBON REVERSE SHAFT 47–0109–000...