3
Monitoring the Symmetricom 5087B

Understanding Alarm Output

24
Table 2 Status or alarm binary codes
Status or alarm
Bit position
character
position
b or g
15
14
13
12
c or h
11
10
9
8
d or i
7
6
5
4
e or j
3
2
1
0
The Symmetricom 5087B automatically publishes alarms to the CNR
port as they occur.
The alarms appear in the format ALARMabcde where abcde is the
summary status of the input and output signals. The format of the alarm
status is identical to the "S" command response defined in
page 23.
Example: ALARM00003
This example shows that outputs 1 and 2 have active faults.
Symmetricom 5087B Operations and Maintenance Manual Rev. E
Bit value and description
0 = Channel A active input
1 = Channel B active input
1 = Cannot lock to input B
1 = Cannot lock to input A
1 = Autoswitch occurred
1 = output 12 failed
1 = output 11 failed
1 = output 10 failed
1 = output 9 failed
1 = output 8 failed
1 = output 7 failed
1 = output 6 failed
1 = output 5 failed
1 = output 4 failed
1 = output 3 failed
1 = output 2 failed
1 = output 1 failed
Table 2