INDOOR UNIT INDICATORS
OPERATION INDICATOR
TEMPORARY SWITCH
Use this switch to start and stop when the remote controller does not work. [Use non-conductor stick
(example: toothpick)]
By pressing the temporary switch, the operation is done in previously set operation mode.
When the operation is done using the temporary switch after the power source is turned off and turn on
again, the operation is done in automatic mode.
FILTER LAMP
When the device is operated for a total of about 200
hours, the FILTER lamp lights to indicate that it is
time to clean the fi lter. The lamp goes out when the
"
(AUTO SWING)" button is pressed while the
device is on "STANDBY MODE".
OPERATION LAMP
This lamp lights during operation.
TIMER LAMP
This lamp lights when the timer is working.