Smart Switch SMS-2 Installation & Operation Manual Features - Model SMS-2 • Receive text messages on your cell phone alerting you to potential problems anywhere in the world • Send commands to control lights, pumps, appliances, air conditioning, etc. via text message from your cell phone •...
Smart Switch SMS-2 Installation & Operation Manual System SIM Card SIM Card Ezy Switch Ltd Terminal 1 Signal LED Signal LED: If the LED flashes once every 1 second, this indicates the cellular network cannot be found (out of GSM coverage range). Remedy = Re-locate the device or use a longer aerial or signal booster.
Smart Switch SMS-2 Installation & Operation Manual Inputs The SMS-2 has two (2) Inputs and can be connected as per Fig 1a /Fig1b or Fig 2 +10 - 30vdc Fig 1a Switch Input 1 Terminal 4 SMS-2 +10 - 30vdc...
SMART Switch SMS-2 Installation & Operation Manual !! IMPORTANT !! Setting up system for the first time: Please ensure the SIM card does NOT have a PIN number or is locked has been ACTIVATED with the network provider, insert into SIM slot on the back (see page 4) and power the unit up.
Smart Switch SMS-2 Installation & Operation Manual Commands Adding a User (Note: Setting up the first user page 7 must be done first) Add user +??XXXXXXXX Country Code page 7) (see Command: If the master is already in the list, the system responds with:...
Command: (System default = On) If Text all is On the SMS-2 will text all user that have been programmed into the unit with the reply to the command. If Text all is Off the SMS-2 will only text the number that initiated the command with the reply.
Smart Switch SMS-2 Installation & Operation Manual Turn all Input Text’s OFF With alerts turned off the device will NOT text every time any Input changes but the Inputs are still active so you can send a “Input status” query at any time.
Once the name has been changed, the particular Input or Output is always referred to by the new name (e.g. Alarm). For commands or status interrogation and the SMS-2 will respond using the new name. Use table on page 20 to record your new Input and Output names.
Smart Switch SMS-2 Installation & Operation Manual Change Input to Normally Open or Normally Closed Make INPUT NAME active open (or) closed Command: This command is used to define if the switch wired to the Input is normally open or normally closed.
Smart Switch SMS-2 Installation & Operation Manual Link an Input to an Output Link INPUT NAME to OUTPUT NAME Command: (Example: Link alarm to siren) The system responds with: The INPUT NAME has been linked to OUTPUT NAME To clear a link...
Smart Switch SMS-2 Installation & Operation Manual Turn an Output ON or OFF Turn OUTPUT NAME on (or) off Command: (Example: Turn Generator on) If everything is fine, the system responds with: OUTPUT NAME has been turned off (or) on This command is used to turn on/off Outputs.
Smart Switch SMS-2 Installation & Operation Manual Make an Output pulse On and Off Make OUTPUT NAME pulse XX secs Command: This sets the output pulse time, XX can be between 1 and 99 seconds When the Output ON command is sent as follows:...
Smart Switch SMS-2 Installation & Operation Manual Turn Output response On / Off This command is used to turn the output response text On or Off. If the output response is turned off then a response text is not sent when outputs are turned on or off System default is ON (send response).
Smart Switch SMS-2 Installation & Operation Manual Link the Battery Alarm to an Output Link battery alarm to OUTPUT NAME Command: The system responds with: The battery alarm has successfully been linked to OUTPUT NAME and the alarm has been reset...
Smart Switch SMS-2 Installation & Operation Manual Alive text feature. (only available in ver 1.2 or latter) This unit has an alive text feature which will send out a alive text as often as it has been programmed for. To turn the feature on:...
Smart Switch SMS-2 Installation & Operation Manual Get Firmware Version Command: The system responds with: SMS-2 Ver X.X Get Signal Strenth Command: The system responds with: Currently the signal strength is XX %" Resetting the Unit Reboot Command: The system responds with: Module is not resetting...
Smart Switch SMS-2 Installation & Operation Manual CONDITIONS OF WARRANTY Penguin Electronics Ltd (the manufacturer) warrants that all of its products are free of defects. Any apparent fault will be rectified free of charge by Penguin Electronics Ltd for a...
Smart Switch SMS-2 Installation & Operation Manual Appendix One: Record Your Names for all Inputs and Outputs Active Input Default [Name] (Up to 20 characters ) Latched Linked Open Yes No Name Closed input1 input2 Output output1 output2 Detailed explanation of Input delays:...
Smart Switch SMS-2 Installation & Operation Manual Trouble Shooting Guide PROBLEM CAUSE POSSIBLE SOLUTION LED not flashing No power Check power supply LED fast flashes Cannot find the GSM network 1. Replace aerial with high gain (every 1 second) aerial and never slow 2.
AC outlet on-board your vessel and wired as shown in the diagram below (fig. 1). Name this Input Shore Power using the Command on page 10. If shore power is lost, the SMS-2 will send a text message to all “Masters”...
Intruder Alarm Systems The following configurations define possible solutions for intruder alarms. Like all other alerts provided by the SMS-2, these should be disabled prior to you entering Alerts off the premises. This is easily accomplished by issuing the text command:...
Smart Switch SMS-2 Installation & Operation Manual Door and Window Alarms Alarms sensors for doors and windows generally consist of magnetically held switches. The contacts are normally-closed (NC). If a door/window is opened the circuit is opened generating an alarm. An alarm is also generated if the wire is cut between the sensor and the monitoring system opening the circuit.
Smart Switch SMS-4 Installation & Operation Manual Air Conditioners / Heating Different brands of Air-Con’s use different means of remotely turning On and Off. Type1: If the brand requires that the Output to be turned On and left On then you can use either Output 1 or 4.
Page 27
All technologies, design and Intellectual property is owned by Penguin Electronics Ltd New Zealand Version 2.1...
Need help?
Do you have a question about the SMS-2 and is the answer not in the manual?
Questions and answers