7-4. AUTO Operation
(MODE of the remote control : AUTO)
(1) One of the 2 modes, Cooling or Dry is selected
according to room temperature at which opera-
tion is to start, as shown in Fig. 7-4-1. The Fan
mode will continue until room temperature reaches
a level at which another mode is selected.
Cooling mode
+4
Cooling mode
+1
Dry mode
(The same cooling mode as the room temperature control is set at set temp. –1˚C)
The Louver moved downward.
(The same cooling mode as the room temperature control is set at set temp. –1˚C)
(The same dry operation as the room temperature control is set at set temp. –1˚C)
7-4-1. Temporary Auto
When the TEMPORARY button is pushed, the set tem-
perature is fixed at 24°C and controlled in accordance
with the chart shown in Fig. 7-4-1.
Fig. 7-4-1