netsys NV-600WI User Manual page 30

Managed industrial grade wireless vdsl2 router
Table of Contents

Advertisement

Grounding the NV-600WI
NV-600WI is designed to enhance EMS performance by grounding. NV-600WI comes with metal DIN-Rail brackets for grounding the
switches. For optimal EMS performance, connect the ground lug at the right of the NV-600WI side panel to the grounding point.
Before installing and powering the device, please read and follow these essentials:
Use separate paths to route wiring for power and devices. If power wiring and device wiring paths must cross make sure the
wires are perpendicular at the intersection point.
Note:
Do not run signal or communications wiring and power wiring through the same wire conduit. To avoid interference, wires with
different signal characteristics should be routed separately.
You can use the type of signal transmitted through a wire to determine which wires should be kept separate. The rule of thumb
is that wiring sharing similar electrical characteristics can be bundled together.
You should separate input wiring from output wiring.
We recommend that you mark all equipment in the wiring system.
NV-600WI Managed Industrial Grade Wireless VDSL2 Router USER'S MANUAL Ver. A2
29

Advertisement

Table of Contents
loading

Table of Contents