Taking The System Out Of Service; Draining The System In Case Of Frost - Buderus 500 - 24/S User Manual

Gas wall hung boiler condensing
Table of Contents

Advertisement

11

Taking the system out of service

Push the mains power switch (fig. 4, item 1) to "
Close the gas service valve by turning it clockwise
(fig. 7, item 1).
Frost protection
The boiler has an automatic frost protection. When the CH flow
temperature drops below 7 °C then the boiler will start up.
11.1

Draining the system in case of frost

It is not recommended, but if the boiler needs to be shut down
for a longer period of time, then it is necessary to drain the sys-
tem. Especially when there is a chance for frost conditions.
Turn off the boiler by setting the mains power to "0" (fig. 4,
item 1).
Close the gas valve (fig. 7, item 1).
Drain the system at its lowest point using the stop valves or
radiator (see fig. 8). The automatic air vent at the system's
highest point must be open.
Subject to modifications resulting from technical improvements!
Users manual for Buderus 500 - 24/S • edition 02/2006
0
".
fig. 7
fig. 8
Users manual
2
1
1: Gas valve closed
2: Gas valve open
Gas service valve
Draining the system
Buderus • http://www.buderus-domestic.co.uk
9

Advertisement

Table of Contents
loading

This manual is also suitable for:

500-24/s

Table of Contents