Ir Transmitter Adjustments (Ccd-Tr713E/Trv46E); Ir Video Carrier Frequency Adjustment (Vc-215 Board); Ir Video Deviation Adjustment (Vc-215 Board) - Sony CCD-TR315E Service Manual

Handycam & handycam vision video camera recorder 8 & hi8 video
Hide thumbs Also See for CCD-TR315E:
Table of Contents

Advertisement

3-5.
IR TRANSMITTER ADJUSTMENTS
(CCD-TR713E/TRV46E)
Adjust using a IR receiver jig (J-6082-383-A).
Switch setting:
LASER LINK .................... (Red LED is lit)

1. IR Video Carrier Frequency Adjustment (VC-215 board)

Mode
Camera standby
Subject
Arbitrary
Pin 5 of CN003 of IR receiver jig (RF)
Measurement Point
( Or Pin !§ of IC751 of VC-215 board)
Measuring Instrument
Frequency counter
Adjustment Page
F
Adjustment Address
68
Specified Value
f = 11.85±0.05MHz
Connection of Equipment
Connect the measuring device as shown in the following figure,
and adjust.
Main unit
IR receiver jig
Fig. 5-3-17.
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 3, address: 01, set data: 37, and press the PAUSE
button of the adjusting remote commander.
3) Select page: F, address: 68, change the data, and set the video
carrier frequency (f) to the specified value.
4) Press the PAUSE button of the adjusting remote commander.
5) Select page: 3, address: 01, set data: 00, and press the PAUSE
button of the adjusting remote commander.
6) Select page: 0, address: 01, and set data: 00.
Frequency counter
Pin 5
of CN003

2. IR Video Deviation Adjustment (VC-215 board)

Mode
Subject
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value
Connection of Equipment
Connect the measuring device as shown in the following figure,
and adjust.
IR receiver jig
Main unit
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 3, address: 01, set data: 39, and press the PAUSE
button of the adjusting remote commander.
3) Select page: F, address: 66, and change the data, set the video
signal amplitude (A) to the specified value.
4) Press the PAUSE button of the adjusting remote commander.
5) Select page: 3, address: 01, set data: 00, and press the PAUSE
button of the adjusting remote commander.
6) Select page: 0, address: 01, and set data: 00.
5-56
Camera standby
Arbitrary
VIDEO OUT terminal of IR receiver jig
(Terminated at 75Ω)
Oscilloscope
F
66
A = 0.87±0.04V
Oscilloscope
75 Ω
VIDEO
OUT
75 Ω (1-247-804-11)
Fig. 5-3-18.
H
Fig. 5-3-19.
A

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents