8-4-4. Piping and Drain Hose Installation

<In case of rightward piping>
• After scribing slits of the front panel and the rear
panel by a knife or a marking-off pin, cut them by a
pair of nippers or the like.
Slit (front panel)
Slit (rear panel)
Fig. 8-4-12
<In case of downward piping>
• After scribing the slit of the front panel and slit in
the lower part of the rear panel by a knife or a
marking-off pin, cut them by a pair of nippers or
the like.
Slit (rear panel)
Fig. 8-4-13
<Left-hand connection with piping>
Bend the connecting pipe so that it is laid within 43
mm above the wall surface. If the connecting pipe is
laid exceeding 43 mm above the wall surface, the
indoor unit may unstably be set on the wall. When
bending the connecting pipe, make sure to use spring
bender so as not to crush the pipe.
Bend the connection pipe within a radius of 30
mm.
Slit (front panel)
– 30 –
To connect pipe after installation of unit (figure)
(To the forefront of flare)
196mm
Side of liquid flow
96mm
Side of gas flow
R 30mm (Use polisin or the like for bending pipe.)
Use the handle of screwdriver,etc.
Fig. 8-4-14
NOTE :
If the pipe is bent incorrectly, the indoor unit may
unstably be set on the wall.
After passing the connecting pipe through the pipe
hole, connect the connecting pipe to auxiliary pipes
and wrap the facing tape around them.
CAUTION
• Bind the auxiliary pipes (two) and connecting
cable with facing tape tightly. In case of leftward
piping and rear-leftward piping, bind the
auxiliary pipes (two) only with facing tape.
Auxiliary
pipes
Installation
plate
• Carefully arrange pipes so that any pipe does
not stick out of the rear plate of the indoor unit.
• Carefully connect the auxiliary pipes and
connecting pipes to each other and cut off the
insulating tape wound on the connecting pipe
to avoid double-taping at the joint, moreover,
seal the joint with the vinyl tape, etc.
• Since dewing results in a machine trouble,
make sure to insulate both the connecting
pipes. (Use polyethylene foam as insulating
material.)
• When bending a pipe, carefully do it not to
crush it.
Outward form of indoor unit
Indoor unit
Connecting