Outside Fresh-Air Connection; Exhaust And Fresh Air Intake Locations - Vistaflame VF 170B Technical Manual

Pellet stove
Table of Contents

Advertisement

o
f
-a
utSide
reSh
ir
This Heater must have adequate air for proper combustion in the room that it is installed.
A Fresh-air intake is strongly recommended for all
installations. Failure to install intake air may result in
improper combustion as well as the unit smoking during
power failures.
The inlet to the intake must be below and a minimum of
12" (30cm) away from the unit exhaust outlet.
Outside fresh air is mandatory when installing this
unit in airtight homes and mobile homes.
When connecting to an outside fresh air source, do not
use plastic or combustible pipe. A 3" minimum (76 mm)
ID (inside diameter) steel, aluminum or copper pipe or
ducting should be used. It is recommended, when you are
installing a fresh air system, to keep the number of bends
in the pipe to a minimum.
e
a
f
xhauSt
nd
reSh
This unit uses a 4" exhaust vent.
EXHAUST:
Base of unit to center of flue
min. 14
/
3
16
Center of unit to center of flue
4
"
/
3
16
FRESH AIR INTAKE.
Base of unit to center of intake
min. 14
/
3
16
Center of unit to center of intake
5⅛"
10
Installation
c
:
onnection
a
i
l
ir
ntake
ocationS
"
(361 mm)
(107 mm)
(361mm)
"
(361 mm)
(130 mm)
3" ID
(76 mm)
:
14
/
"
3
16
Figure 9: VF170 Inlet and Outlet Location.
Outside
Wall
Figure 8: Outside Air Connection.
5
/
"
4
/
"
1
3
8
16
(130mm)
(107mm)
Optional
Elbow

Advertisement

Table of Contents
loading