3. ELECTRICAL ADJUSTMENT
3-1. Table for Servicing Tools
Ref. No.
Name
J-1
Color viewer
J-2
Siemens star chart
J-3
Calibration software
J-4
Spare lamp
J-5
Pictured jig
J-6
Strobe adjustment box
J-7
CCD calibration
Note: J-1 color viewer is 100 - 110 VAC only.
J-1
J-3/J-7
J-5
3-2. Equipment
1. Oscilloscope
2. Digital voltmeter
3. AC adaptor
4. PC (IBM R -compatible PC, Pentium processor, Window
98 or Me)
5. Monitor TV
6. USB cable
3-3. Adjustment Items and Order
1. 5.1 V (A) Voltage Adjustment
2. Back Focus Adjustment
3. CCD Adjustment
4. Strobe Adjustment
Part code
VJ8-0007
VJ8-0186
VJ8-0028
VJ8-0181
VJ8-0182
VJ8-0185
J-2
J-4
J-6
5. LCD Panel Adjustment
5-1. LCD H AFC Adjustment
5-2. LCD RGB Offset Adjustment
5-3. LCD Gain Adjustment
5-4. LCD Red Brightness Adjustment
5-5. LCD Blue Brightness Adjustment
3-4. Setup
1. System requirements
Windows 98 or Me
IBM R -compatible PC with pentium processor
CD-ROM drive
3.5-inch high-density diskette drive
USB port
40 MB RAM
Hard disk drive with at least 15 MB available
VGA or SVGA monitor with at least 256-color display
2. Installing calibration software
1. Insert the calibration software installation diskette into your
diskette drive.
2. Open the explorer.
3. Copy the DscCalDI_128a folder on the floppy disk in the
FD drive to a folder on the hard disk.
3. Installing USB drive
Install the USB drive with camera or connection kit for PC.
4. Color Viewer
1. Turn on the switch and wait for 30 minutes for aging to take
place before using Color Pure.
2. The luminance adjustment control on the color viewer
should be set to around the middle position (memory 5)
during use.
3. The fluorescent lamps which are used in the color viewer
are consumable parts. After the cumulative usage time
reaches 2000 hours, the color temperature will start to in-
crease as the usage time increases, and correct adjust-
ment will not be possible. When the cumulative usage time
reaches 2000 hours, all of the fluorescent lamps should be
simultaneously replaced with new lamps.
5. Computer screen during adjustment
Calibration
Upload
AWB
Firmware
Focus
Image
UV Matrix
Cal Mode
Initialize
OK
EVF
Cal Data
LCD Type
OK
Firmware Version:
USB storage
Get
VID
PID
Set
– 13 –
LCD
R Bright
B Bright
RGB Offset
Gain
Tint
Phase
VCO
H AFC
Test
Set
Serial
Set
Set
Rev.
Set
VCOMDC
VCOMPP
Setting
Language
Video Mode

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vpc-r1exVpc-r1gVar-g5uVar-g5exVar-g5eVpc-r1

Table of Contents