FLUE TERMINAL CLEARANCES

REF
A
Clearance above grade, veranda, porch, deck or snowline
B
Clearance to window or door that may be opened
C
Clearance to permanently closed window
D
Vertical clearance to ventilated soffit, located above the terminal within
a horizontal distance of 2 feet (61 cm) from the center line of the terminal
E
Clearance to unventilated soffit
F
Clearance to outside corner
G
Clearance to inside corner
H
Clearance to each side of center line extended above meter/regulator
assembly
I
Clearance to service regulator vent outlet
J
Clearance to nonmechanical air supply inlet to building or
the combustion air inlet to any other appliance
K
Clearance to a mechanical air supply inlet
L
Clearance above paved sidewalk or paved driveway located on public property
M
Clearance under veranda, porch, deck or balcony
*For clearances not specified in ANSI Z223.1/NFPA 54, clearances are in accordance with local installation codes and the requirements of the gas supplier.
Clearance to opposite wall is 24 inches (60 cm).
1 A vent shall not terminate directly above a sidewalk or paved driveway that is located between two single family dwellings and serves both dwellings.
2 Permitted only if veranda, porch, deck or balcony is fully open on a minimum of two sides beneath the floor.
FLUE TERMINAL CLEARANCES (ANSI Z21.10.3 • CSA 4.3)
Installation Instructions
DESCRIPTION
2
6
U.S. INSTALLATIONS
CLEARANCES PER
ANSI Z21.10.3
36 inches (91 cm)
12 inches (30 cm)
*
*
*
*
*
*
*
12 inches (30 cm)
3 feet (91 cm) above
if within 10 feet
(3 m) horizontally
1
*
*