HIGH ALTITUDE INSTALLATIONS

Set dip switches 2 and 3 to the values shown in the
table below for your altitude. The default setting for
the appliance is 0-2000 ft (0-610 m) with switches
No. 2 and No. 3 in the OFF position.
0–2000 ft.
(0–610 m)
Switch No. 2
Switch No. 3
O
F
F
CASCADING MULTIPLE WATER HEATERS
The Dual Connect Cable Kit (AGTDC1) is an optional
accessory that connects 2 water heaters and allows
them to function as one hot water source.
The Multi Connect Kit (AGTCK1) and the Multi Connect
Cable Kit (AGTMC1) are optional accessories that
connect 3 to 5 water heaters and allow them to
function as one hot water source.
Refer to the instructions that come with the accessory
for complete installation information.
NUMBER OF CONNECTED WATER HEATERS
2
3
4
5
Connecting Two Units
Installation Instructions
2001–5200 ft.
(610–1585 m)
OFF
OFF
Switch No.
Switch No.
ON
O
1
F
F
2
3
4
5
6
7
8
(1) Multi Connect Kit (AGTCK1) and (1) Multi Connect Cable Kit (AGTMC1)
(1) Multi Connect Kit (AGTCK1) and (2) Multi Connect Cable Kits (AGTMC1)
(1) Multi Connect Kit (AGTCK1) and (3) Multi Connect Cable Kits (AGTMC1)
WARNING:
dip switches unless specifically instructed to do so.
If unsure of the altitude in your location, call
1.888.HOTWTER (888.467.9837).
5201–7700 ft.
(1585–2347 m)
OFF
ON
ON
OFF
Switch No.
ON
O
1
F
F
2
3
4
5
6
7
8
GUIDELINES
• Do not install the Dual Connect Cable Kit (AGTDC1)
with the Multi Connect Kit (AGTCK1) and the Multi
Connect Cable Kit (AGTMC1) because they are not
designed to operate together.
• Water heaters should be installed less than
18 inches apart so that the cables will reach
between units and to prevent temperature
fluctuations (cold water sandwich effect) when
the water is shut off and turned back on.
• Temperature settings can only be changed on
the controller for the primary unit.
ACCESSORIES NECESSARY
(1) Dual Connect Cable Kit (AGTDC1)
Connecting Five Units
21
Do not adjust the other
7701–10200 ft.
(2347–3109 m)
ON
ON
Switch No.
ON
ON
O
1
F
F
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gp94dnsrsaGn94dnsrsa