Operating Instructions

Electrical Operation

The BG770 and BG790 barrier gate operators are designed to provide years of trouble-free operation.
The gate may be operated by means of the two button control station, or by other means if provided.
ON/OFF POWER SWITCH
The gate is provided with an ON/OFF power switch. To shut power off, remove the access cover
and move the toggle switch on the right side of the main electrical cabinet to the "OFF" position.
OVERLOAD PROTECTION
The motor is protected by either a manual reset (Single Phase unit) or automatic reset (3 phase
unit) thermal overload protector. The overload protector will trip when the motor temperature is
too hot.
DO NOT ATTEMPT TO BYPASS THIS UNIT
If the overload trips, the gate could start by itself when the overload is reset (either manual or
automatic). Exercise caution when resetting the overload. On one phase units, the reset
button is located on the cover of the electrical cabinet.
If after resetting, the overload continues to trip, consult a qualified service company.

Manual Operation

CAUTION
Keep hands clear of moving parts. The motor will start when AUTO/MANUAL Switch is
flipped to the "MANUAL" position.
ACCESS CONTROL "EMERGENCY" BYPASS
To open the gate in an emergency, remove the keyed access cover and open the electrical
cabinet. Flip the AUTO/MANUAL switch to the "MANUAL" position.
The gate arm will remain in the up position, and no other control device will have any effect until
the switch is set back to the "AUTO" position.