Adaptive Micro Systems alpha User Manual page 14

Serial clock
Hide thumbs Also See for alpha:
Table of Contents

Advertisement

ALPHA Serial Clock Manual
Offset
DIP 1
DIP2
Hours
+0
OFF
OFF
+1
ON
OFF
+2
OFF
ON
+3
ON
ON
+4
OFF
OFF
+5
ON
OFF
+6
OFF
ON
+7
ON
ON
+8
OFF
OFF
+9
ON
OFF
+10
OFF
ON
+11
ON
ON
+12
OFF
OFF
+13
ON
OFF
+14
OFF
ON
+15
ON
ON
14
Table 4: DIP Switch Settings
(DIP #8 should always be OFF — see page 17.
To set DIP #5 — see page 17.)
DIP3
DIP4
DIP7
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
ON
OFF
ON
ON
OFF
ON
ON
OFF
ON
ON
OFF
ON
ON
OFF
Offset
DIP 1
DIP2
Hours
-0
OFF
OFF
-1
ON
OFF
-2
OFF
ON
-3
ON
ON
-4
OFF
OFF
-5
ON
OFF
-6
OFF
ON
-7
ON
ON
-8
OFF
OFF
-9
ON
OFF
-10
OFF
ON
-11
ON
ON
-12
OFF
OFF
-13
ON
OFF
-14
OFF
ON
-15
ON
ON
DIP3
DIP4
DIP7
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
ON
ON
OFF
ON
ON
OFF
ON
ON
OFF
ON
ON
OFF
ON
OFF
ON
ON
OFF
ON
ON
OFF
ON
ON
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON

Advertisement

Table of Contents
loading

This manual is also suitable for:

Alpha

Table of Contents