Mantel Clearances; Floor Clearances - Comfort Glow CGS2718P Owner's Operation And Installation Manual

Royal english oak, biltmore split oak, and winchester oak unvented (vent-free) propane/lp gas log heater
Table of Contents

Advertisement

INSTALLATION
Continued

MANTEL CLEARANCES

In addition to meeting noncombustible mate-
rial clearances, you must also meet required
clearances between fireplace opening and
mantel shelf. If you do not meet the clear-
ances listed below, you will need a hood.
Determining Mantel Clearance
If you meet minimum clearance between
mantel shelf and top of fireplace opening, a
hood is not required (see Figure 6).
Determining Minimum Mantel
Clearance when Using a Hood
If minimum clearances in Figure 6 are not
met, you must have a hood. When using a
hood there are still certain minimum mantel
clearances required. Follow minimum clear-
ances shown in Figure 7 when using a hood.
NOTICE: If your installation does
not meet the minimum clearances
shown, you must do one of the
following:
• operate the logs only with the
flue damper open
• raise the mantel to an accept-
able height
• remove the mantel

FLOOR CLEARANCES

A. If installing appliance on the floor
level, you must maintain the minimum
distance of 14" to combustibles (see
Figure 8).
B. If combustible materials are less than
14" to the fireplace, you must install
appliance at least 5" above the combus-
tible flooring (see Figure 9).
104386
10"
8"
6"
1 /2
2
"
Minimum Non-
(A)
Combustible
Material
12"
8"
Minimum Non-
Combustible
Material Height
Figure 6 - Minimum Mantel Clearances Without Using Hood
12"
10"
8"
6"
1 /2
2
"
Minimum Non-
Combustible
Material
Hood
(GA6050, GA6052,
(GA6050, GA6052)
or GA6053)
Figure 7 - Minimum Mantel Clearances When Using Hood
14"
Min.
Noncombustible Material
Figure 8 - Minimum Fireplace Clearances
If Installed at Floor Level
9
OWNER'S MANUAL
Mantel Shelf
Underside of
Mantel Shelf
All minimum
distances are
in inches
18"
20"
22"
24"
3 /4
8"
14"
16
"
20"
Top of Fireplace
Opening
Distances to
Underside of
Mantel
Mantel Shelf
8"
12"
15"
18"
Min.
Distances to
Underside of
Mantel
Combustible
Material
Figure 9 - Minimum Fireplace Clearances
Above Combustible Flooring
Log Set
24" Model
18" Model
Underside of
Mantel Shelf
All minimum
distances are
in inches
Log Set
20"
18" and 24"
Models
Top of Fireplace
Opening
Hearth
Combustible
Material
5"
Min.
Continued

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ccl3930ptCgs3124pCld3018pCcl3930ptaCld3924pt

Table of Contents