Redline Communications AN-50e User Manual page 80

An-50e system ptp / pmp user manual
Hide thumbs Also See for AN-50e:
Table of Contents

Advertisement

Table 29 : Spec. - AN-50e Technical Specifications
Wireless Transmission:
Network Connection:
System Configuration:
Network Management:
Power Requirements:
Redundant Power:
Compliance:
Operating Temperature:
Dimensions/Weight:
Humidity:
Weight:
1
Center frequency is dependent on region.
2
Actual Ethernet data throughput is dependent on: protocols, packet size, burst rate,
transmission latency, and link distance.
3
In some countries outside of North America, the maximum operational power per
channel with a given antenna is limited in accordance to maximum allowable EIRP
levels for the region.
4
With two lightning arrestors installed.
5
Point-to-Point Mode only.
6
Point-to-Multipoint mode only.
Subject to change without notice.
70-00033-01-03
OFDM (orthogonal frequency division multiplexing)
10/100 Ethernet (RJ-45)
HTTP (Web) interface, SNMP
CLI via Telnet and local console
SNMP: standard and proprietary MIBs
Full management by RedAccess NMS
39 W maximum
Single/dual auto-sensing 110/220/240 VAC 50/60 Hz
Single/dual 18 - 72 VDC
Optional dual AC or dual DC power supply (dual cord)
with automatic fail-over
EN 60950, EN 301 893, EN 301 390, EN 301 489-1 & 17,
FCC part 15, UL 60950, IEC 60950
IDU Operating Cond.: 5 C to 40 C,
IDU Short-Term Cond.: -5 C to 55 C for up to 16 hours
ODU Operating Cond.: -40 C to 60 C
IDU: 431.8 x 304.8 x 44.45 mm (17 x 12 x 1.75 in)
IDU: Up to 95% non-condensing
2.5 Kg (5.5 lb)
Proprietary Redline Communications © 2005