Classifi-
Code
cation
870
Separa-
Separation transformer DC
tion
correction (H)
871
Separa-
Separation transformer DC
tion
correction (L)
872
Laser
Laser power correction
(Normal)
873
Laser
Laser power correction
(Text/Photo)
875
Laser
Laser power correction
(Toner saving mode)
876
Laser
Laser power correction
(Text)
877
Laser
Laser power correction
(Photo)
883
Laser
Laser power
correction
(Normal)
886
Fuser
Temperature drop control
setting in ready status
(Temperature/Time)
896-0
Fuser
Temperature
control lower
limit
(Plain paper/
Low tempera-
896-1
ture)
900
Version
System firmware ROM ver-
sion
December 2005 © TOSHIBA TEC
Setting mode (08)
Default
Func-
<Accept-
Items
tion
value>
ALL
<0-255>
ALL
<0-255>
PRT
<0-255>
PPC
<0-255>
PRT
<0-255>
PPC
<0-255>
PPC
<0-255>
GDI
PRT
<0-255>
ALL
<0-20>
Center
ALL
themistor
<0-12>
Side
ALL
themistor
<0-12>
ALL
e-STUDIO163/203 ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 59
RAM
Contents
able
128
M
Corrects the value of
the separation trans-
former DC output
adjustment (05-233).
128
M
Corrects the value of
the separation trans-
former DC output
adjustment (05-235).
128
M
Corrects the value of
the laser power adjust-
ment (05-286).
128
M
Corrects the value of
the laser power adjust-
ment (05-286).
128
M
Corrects the value of
the laser power adjust-
ment (05-286).
128
M
Corrects the value of
the laser power adjust-
ment (05-286).
128
M
Corrects the value of
the laser power adjust-
ment (05-286).
136
M
4
M
0: None
1: Pattern 1
2: Pattern 2
3: Pattern 3
4: Pattern 4
5: Pattern 5
6: Pattern 6
7: Pattern 7
8: Pattern 8
9: Pattern 9
10: Pattern 10
11: Pattern 11
12: Pattern 12
13: Pattern 13
14: Pattern 14
15: Pattern 15
16: Pattern 16
17: Pattern 17
18: Pattern 18
19: Pattern 19
20: Manual adjustment
7
M
0: 130°C
2: 140°C
4: 150°C
6: 160°C
8: 170°C
5
M
10: 180°C
11: 185°C
12: 120°C
-
-
T280SY0Wxxx
Displays only the "xxx"
part of the above code.
Proce-
dure
1
1
1
1
1
1
1
1
1
1: 135°C
4
3: 145°C
5: 155°C
7: 165°C
9: 175°C
4
2
2

Hide quick links:

Advertisement

loading

This manual is also suitable for:

E-studio 203