3. Check the location acceptability before beginning
the installation.
a. If possible mount the air conditioner in a section
of the roof which is both flat and level when the
caravan is parked on a level surface; otherwise,
a sideways pitch or forward pitch up to 8° can be
tolerated, but a backward pitch can never be
accepted. See FIG. 3.
FIG. 3
Good
Side
8° With A/C
Facing Forward
b. Check on the roof to insure no obstructions are
in the area where the air conditioner will be
installed. See FIG. 4 & 5.
10 cm
FIG. 4
18 cm
10.5 cm
35.5 x35.5 cm
OPENING
18 cm
KEEP THESE AREAS
FREE OF OBSTRUCTIONS
7.5 cm
51 cm
10 cm
OK
Side
10 cm
REAR
54 cm
OF
UNIT
Center Line
of Unit
30 cm
Air Box
PERIMETER
35.5 x35.5 cm
OPENING
Center Line
of Unit
10 cm
7.5 cm
56 cm
Type 3253.332 Installation and Operating Instructions
FIG. 5
97 cm
56 cm
6.4 cm
c. Check inside the Caravan for air box obstruc-
tions (i.e. door openings, room dividers, cur-
tains, ceiling fixtures, etc.) See FIG. 6.
Roof /Return Air Grill - Cross
Prohibits Installation
FIG. 6
Cabinet - Prohibits Use
d. The roof must be designed to support 60 Kg.
when the Caravan is in motion. Normally a 90
Kg. static load design will meet this require-
ment. See FIG. 7.
It is the responsibility of the installer of this
air conditioner system to ensure structural in-
tegrity of the Caravan roof. Never create a low
spot on the roof where water will collect. Wa-
ter standing around the air conditioner may
leak into the interior causing damage to the
product and the Caravan.