Acorn A172108F-UBL Installation, Operation And Maintanance Manual

Refrigerated universal bi-level barrier free, wall mounted water cooler

Advertisement

Quick Links

Alternate Configuration
A172108F-UBL / A172408F-UBL / A172108F-SO / A172408F-SO
TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER:
NOTES TO INSTALLER:
1. Please leave this documentation with the owner of the fixture when finished.
2. Please read this entire booklet before beginning the installation.
3. Check your installation for compliance with plumbing, electrical and other applicable codes.
Acorn Engineering warrants Water Coolers, Drinking Fountains and remote Chillers are free from defects in
material or workmanship under normal use and service for a period of one year from date of shipment from the
factory. The compressor, condenser and refrigeration tubing is warranted for an additional four years after the
period described above. Acorn's liability under this warranty shall be discharged solely by repair or replacement
of defective material, provided Acorn is notified in writing within the time periods described above.
This warranty does not cover installation or labor charges and does not apply to materials, which have been
damaged by other causes such as mishandling or improper care or abnormal use. The repair or replacement of
the defective materials shall constitute the sole remedy of the Buyer and the sole remedy of Acorn under this
warranty. Acorn shall not be liable under any circumstances for incidental, consequential or direct charges
caused by defects in the materials, or any delay in the repair or replacement thereof. This warranty is in lieu of
all other warranties expressed or implied. Product maintenance instructions are issued with each unit and
disregard or non-compliance with these instructions will constitute an abnormal use condition and void the
warranty. Stainless steel must be protected on jobsite during construction and must be properly maintained
after the water has been introduced into the water cooler or drinking fountain, or Acorn's limited warranty is
void.
LIMITED EXPORT WARRANTY - One year on parts only.
Acorn Engineering Company™ assumes no
responsibility for use of void or superseded data.
© Copyright Acorn Engineering, City of Industry,
CA Member of Morris Group International.
Please visit
www.acorndrinkingfountains.com
for most current specifications.
7020-905-001
Date: 08/11/14
INSTALLATION, OPERATIONS
& MAINTENANCE MANUAL
A172.8UBL Series
Refrigerated Universal Bi-Level
Barrier Free, Wall Mounted Water Cooler
OR
1.800.591.9360
Technical Assistance Fax: 1.626.855.4894
LIMITED WARRANTY - UNITED STATES & CANADA
Federal
Test rating conditions are
Public Law
111-380
compliant with ARI 1010.
(No Lead)
Standard Configuration
Member of
w w w. a c o r n d r i n k i n g f o u n t a i n s . c o m
ACORN
Water Coolers &
Drinking Fountains
15125 Proctor Ave.
City of Industry, CA
91746 U.S.A.
Phone 800-591-9360
626-336-4561

Advertisement

loading
Need help?

Need help?

Do you have a question about the A172108F-UBL and is the answer not in the manual?

Questions and answers

Summary of Contents for Acorn A172108F-UBL

  • Page 1 The repair or replacement of the defective materials shall constitute the sole remedy of the Buyer and the sole remedy of Acorn under this warranty. Acorn shall not be liable under any circumstances for incidental, consequential or direct charges caused by defects in the materials, or any delay in the repair or replacement thereof.
  • Page 2 2. Provide clear floor space as required. Adjust vertical dimensions as required to comply with federal, state, and local codes. See next page for alternative mounting of units, roughing-in and dimensional drawing. ACORN ENGINEERING FIELD SERVICE TOLL FREE 800-743-8259 • LOCAL 626-855-4866 • FAX 626-855-4863 Date: 08/11/14...
  • Page 3 Acorn Engineering. 10. Fixture operates within water pressure range of 20 to 105 psig. Acorn Engineering will not warranty fixtures damaged when connected to supply lines with flow pressure lower than 20 psig or higher than 105 psig.
  • Page 4 STANDARD WASTE CONFIGURATION ALTERNATE WASTE CONFIGURATION 11. Due to cold waste water, Acorn Engineering recommends that p-trap supplied by installer be insulated to prevent excessive condensation. 12. Per UPC 609.10- All building water supply systems in which quick acting valves are installed shall be provided with devices to absorb the hammer caused by high pressure resulting from the quick closing of the valve.
  • Page 5: Troubleshooting

    The water cooler must be taken to a certified refrigerant technician for repairs. b. Make sure the condenser fan motor is operative. The fan blade must turn freely to help remove the heat of compression. ACORN ENGINEERING FIELD SERVICE TOLL FREE 800-743-8259 • LOCAL 626-855-4866 • FAX 626-855-4863 Date: 08/11/14...
  • Page 6 They can scratch easily and should only be cleaned using a clean, soft cloth and mild soap with water or a mild glass cleaner. ACORN ENGINEERING FIELD SERVICE TOLL FREE 800-743-8259 • LOCAL 626-855-4866 • FAX 626-855-4863 Date: 08/11/14...
  • Page 7 FLOW REGULATOR CARTRIDGE(05 GPMG) 7003-095-001 VALVE ASSEMBLY Repairs must be made with Acorn Engineering parts only. Please order through your local representative or distributor. The phone to locate your local representative is 1.800.591.9360 ACORN ENGINEERING FIELD SERVICE TOLL FREE 800-743-8259 • LOCAL 626-855-4866 • FAX 626-855-4863...
  • Page 8: Push-In Fitting Installation

    Push collet square towards the push-in fitting body and hold. While holding the collet in, pull on the PE tubing to remove from the push-in fitting. COLLET ACORN ENGINEERING FIELD SERVICE TOLL FREE 800-743-8259 • LOCAL 626-855-4866 • FAX 626-855-4863 Date: 08/11/14 7020-905-001...
  • Page 9 15" 15 16 Standard A172.8UBL series refrigerated ADA cooler shown. All 1/4" O.D. Plastic tubing 15 must be insulated with 16 foam insulation. ACORN ENGINEERING FIELD SERVICE TOLL FREE 800-743-8259 • LOCAL 626-855-4866 • FAX 626-855-4863 Date: 08/11/14 7020-905-001 Page 9 of 11...
  • Page 10 15" 15 16 15 16 Repairs must be made with Acorn Engineering parts only. Please order through your local representative or distributor. The phone number to locate your local representative is 1.800.591.9360. ACORN ENGINEERING FIELD SERVICE TOLL FREE 800-743-8259 • LOCAL 626-855-4866 • FAX 626-855-4863...
  • Page 11 7003-023-199 CARTRIDGE MTG BRACKET, SENSOR OP 7000-050-001 VALVE CARTRIDGE ASSEMBLY Repairs must be made with Acorn Engineering parts only. Please order through your local representative or distributor. The phone number to locate your local representative is 1.800.591.9360. ACORN ENGINEERING FIELD SERVICE TOLL FREE 800-743-8259 •...

This manual is also suitable for:

A172108f-soA172408f-ublA172408f-soA172.8ubl series