Acorn A311108F Installation, Operation & Maintenance Manual

A311.8 series compact and deluxe wall mounted water coolers

Advertisement

Quick Links

Compact and Deluxe Wall Mounted Water Coolers
TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER:
NOTES TO INSTALLER:
1. Please leave this documentation with the owner of the fixture when finished.
2. Please read this entire booklet before beginning the installation.
3. Check your installation for compliance with plumbing, electrical and other applicable codes.
Acorn Engineering warrants Water Coolers, Drinking Fountains and remote Chillers are free from defects in
material or workmanship under normal use and service for a period of one year from date of shipment from the
factory. The compressor, condenser and refrigeration tubing is warranted for an additional four years after the
period described above. Acorn's liability under this warranty shall be discharged solely by repair or replacement
of defective material, provided Acorn is notified in writing within the time periods described above.
This warranty does not cover installation or labor charges and does not apply to materials, which have been
damaged by other causes such as mishandling or improper care or abnormal use. The repair or replacement of
the defective materials shall constitute the sole remedy of the Buyer and the sole remedy of Acorn under this
warranty. Acorn shall not be liable under any circumstances for incidental, consequential or direct charges
caused by defects in the materials, or any delay in the repair or replacement thereof. This warranty is in lieu of
all other warranties expressed or implied. Product maintenance instructions are issued with each unit and
disregard or non-compliance with these instructions will constitute an abnormal use condition and void the
warranty. Stainless steel must be protected on jobsite during construction and must be properly maintained
after the water has been introduced into the water cooler or drinking fountain, or Acorn's limited warranty is
void.
LIMITED EXPORT WARRANTY - One year on parts only.
Acorn Engineering Company™ assumes no
responsibility for use of void or superseded data.
© Copyright Acorn Engineering, City of Industry,
CA Member of Morris Group International.
Please visit
www.acorneng.com
for most
current specifications.
7020-919-001
Date: 06/15/15
INSTALLATION, OPERATIONS
& MAINTENANCE MANUAL
A311.8 Series
A311108F / A311108S / A311108Q
1.800.591.9360
Technical Assistance Fax: 1.626.855.4894
LIMITED WARRANTY - UNITED STATES & CANADA
Test rating conditions are
compliant with ARI 1010.
Water Coolers &
Drinking Fountains
15125 Proctor Ave.
City of Industry, CA
Member of
Phone 800-591-9360
w w w. a c o r n d r i n k i n g f o u n t a i n s . c o m
ACORN
91746 U.S.A.
626-336-4561

Advertisement

loading
Need help?

Need help?

Do you have a question about the A311108F and is the answer not in the manual?

Questions and answers

Summary of Contents for Acorn A311108F

  • Page 1 The repair or replacement of the defective materials shall constitute the sole remedy of the Buyer and the sole remedy of Acorn under this warranty. Acorn shall not be liable under any circumstances for incidental, consequential or direct charges caused by defects in the materials, or any delay in the repair or replacement thereof.
  • Page 2 DIMENSIONS AS NECESSARY TO COMPLY WITH FEDERAL, STATE, & LOCAL CODES. 4. STOP VALVE, TRAP, & ELECTRICAL OUTLET NOT SUPPLIED. 5. IMPORTANT: COOLER MUST BE ATTACHED TO WALL WITH ANCHOR SCREWS. ACORN ENGINEERING FIELD SERVICE TOLL FREE 800-743-8259 • LOCAL 626-855-4866 • FAX 626-855-4863 L1001051...
  • Page 3: Installation

    6. Plug water cooler in to electrical outlet and make sure unit begins to function. 7. Assemble bottom cover to water cooler with screws furnished. ACORN ENGINEERING FIELD SERVICE TOLL FREE 800-743-8259 • LOCAL 626-855-4866 • FAX 626-855-4863 L1001051...
  • Page 4 Acorn Engineering. 10. Fixture operates within water pressure range of 20 to 105 psig. Acorn Engineering will not warranty fixtures damaged when connected to supply lines with flow pressure lower than 20 psig or higher than 105 psig. A pressure regulator must be furnished by others on supply line if inlet pressure is greater than 105 psig.
  • Page 5 This indicates a refrigeration problem or thermostat qualified technician. failure in which case the water cooler needs to be checked by a ACORN ENGINEERING FIELD SERVICE TOLL FREE 800-743-8259 • LOCAL 626-855-4866 • FAX 626-855-4863 L1001051...
  • Page 6 3. Periodically remove access panels and clean out in-line strainer. 4. Do NOT use harsh chemicals, abrasive or petroleum based cleaners. Use of these will void the Acorn Engineering warranty. 5. Exterior panels can be cleaned using mild household detergents or warm, soapy water. Extra care must be used cleaning chrome plated items and mirror finished stainless steel.
  • Page 7: Push-In Fitting Installation

    While holding the collet in, pull on the PE tubing to remove from the push-in fitting. COLLET ACORN ENGINEERING FIELD SERVICE TOLL FREE 800-743-8259 • LOCAL 626-855-4866 • FAX 626-855-4863 L1001051 Page 7 of 9...
  • Page 8 18" 15" 28 27 18" ** 29 NOTE: See next page for table of part numbers corresponding to drawing above. ACORN ENGINEERING FIELD SERVICE TOLL FREE 800-743-8259 • LOCAL 626-855-4866 • FAX 626-855-4863 L1001051 Page 8 of 9 Date: 06/15/15...
  • Page 9 FOAM PIPE INSULATION 3/8" ID x 1/4" THK 7003-093-001 FLOW RESTRICTOR - LOW-FLOW BUBBLER ONLY Repairs must be made with Acorn Engineering parts only. Please order through your local representative or distributor. The phone number to locate your local representative is 1.800.591.9360. ACORN ENGINEERING FIELD SERVICE TOLL FREE 800-743-8259 •...

This manual is also suitable for:

A311108sA311108q