TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER:
NOTES TO INSTALLER:
1. Please leave this documentation with the owner of the fixture when finished.
2. Please read this entire booklet before beginning the installation.
3. Check your installation for compliance with plumbing, electrical and other applicable codes.
Acorn Engineering warrants Water Coolers, Drinking Fountains and remote Chillers are free from defects in
material or workmanship under normal use and service for a period of one year from date of shipment from the
factory. The compressor, condenser and refrigeration tubing is warranted for an additional four years after the
period described above. Acorn's liability under this warranty shall be discharged solely by repair or replacement
of defective material, provided Acorn is notified in writing within the time periods described above.
This warranty does not cover installation or labor charges and does not apply to materials, which have been
damaged by other causes such as mishandling or improper care or abnormal use. The repair or replacement of
the defective materials shall constitute the sole remedy of the Buyer and the sole remedy of Acorn under this
warranty. Acorn shall not be liable under any circumstances for incidental, consequential or direct charges
caused by defects in the materials, or any delay in the repair or replacement thereof. This warranty is in lieu of
all other warranties expressed or implied. Product maintenance instructions are issued with each unit and
disregard or non-compliance with these instructions will constitute an abnormal use condition and void the
warranty. Stainless steel must be protected on jobsite during construction and must be properly maintained
after the water has been introduced into the water cooler or drinking fountain, or Acorn's limited warranty is
void.
LIMITED EXPORT WARRANTY - One year on parts only.
Acorn Engineering Company™ assumes no
responsibility for use of void or superseded data.
© Copyright Acorn Engineering, City of Industry,
CA Member of Morris Group International.
Please visit
www.acorndrinkingfountains.com
for most current specifications.
7020-904-001
Date: 03/12/15
INSTALLATION, OPERATIONS
& MAINTENANCE MANUAL
A171.8 Series
Barrier Free, Wall Mounted Water Cooler
A171108F / A171408F / A171108F-SO / A17408F-SO
1.800.591.9360
Technical Assistance Fax: 1.626.855.4894
LIMITED WARRANTY - UNITED STATES & CANADA
Federal
Public Law
111-380
(No Lead)
Test rating conditions are
compliant with ARI 1010.
Water Coolers &
Drinking Fountains
15125 Proctor Ave.
City of Industry, CA
Member of
Phone 800-591-9360
w w w. a c o r n d r i n k i n g f o u n t a i n s . c o m
ACORN
91746 U.S.A.
626-336-4561

Advertisement

loading
Need help?

Need help?

Do you have a question about the A171.8 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Acorn A171.8 Series

  • Page 1 The repair or replacement of the defective materials shall constitute the sole remedy of the Buyer and the sole remedy of Acorn under this warranty. Acorn shall not be liable under any circumstances for incidental, consequential or direct charges caused by defects in the materials, or any delay in the repair or replacement thereof.
  • Page 2 For Child ADA compliant parallel approach, decrease spout height to 30” maximum above finished floor. Provide clear floor space as required. ACORN ENGINEERING FIELD SERVICE TOLL FREE 800-743-8259 • LOCAL 626-855-4866 • FAX 626-855-4863...
  • Page 3: Prior To Installation

    Acorn Engineering. 10. Fixture operates within water pressure range of 20 to 105 psig. Acorn Engineering will not warranty fixtures damaged when connected to supply lines with flow pressure lower than 20 psig or higher than 105 psig.
  • Page 4: Installation

    6. Plug water cooler in to electrical outlet and make sure unit begins to function. 7. Assemble bottom cover to water cooler with screws furnished. ACORN ENGINEERING FIELD SERVICE TOLL FREE 800-743-8259 • LOCAL 626-855-4866 • FAX 626-855-4863 Date: 03/12/15...
  • Page 5: Troubleshooting

    Check the compressor mounting to make sure the pins and clips are not rattling. If the compressor appears to be noisy internally, it must be replaced. ACORN ENGINEERING FIELD SERVICE TOLL FREE 800-743-8259 • LOCAL 626-855-4866 • FAX 626-855-4863...
  • Page 6 Clean with scale remover. c. There is debris or scale in the center or two holes in convolution of the water diaphragm. Remove and clean. ACORN ENGINEERING FIELD SERVICE TOLL FREE 800-743-8259 • LOCAL 626-855-4866 • FAX 626-855-4863 Date: 03/12/15...
  • Page 7 7003-830-000 UNIVERSAL MAINTANANCE TOOL 7003-864-000 STRAINER FILTER SCREEN 7003-097-001 O-RING &STRAINER PLUG 7000-060-000 FLOW REGULATOR CARTRIDGE(05 GPMG) 7003-095-001 VALVE ASSEMBLY ACORN ENGINEERING FIELD SERVICE TOLL FREE 800-743-8259 • LOCAL 626-855-4866 • FAX 626-855-4863 Date: 03/12/15 7020-904-001 Page 7 of 11...
  • Page 8: Push-In Fitting Installation

    Push collet square towards the push-in fitting body and hold. While holding the collet in, pull on the PE tubing to remove from the push-in fitting. COLLET ACORN ENGINEERING FIELD SERVICE TOLL FREE 800-743-8259 • LOCAL 626-855-4866 • FAX 626-855-4863 Date: 03/12/15 7020-904-001...
  • Page 9 15" 15" ** 26 Standard A171.8 series refrigerated ADA cooler shown. All 1/4" O.D. Plastic tubing 24 must be insulated with 25 foam insulation. NOTE: See next page for table of part numbers corresponding to drawing above. ACORN ENGINEERING FIELD SERVICE TOLL FREE 800-743-8259 •...
  • Page 10 ** Flow Restrictor Only Available With Low Flow Bubbler. Repairs must be made with Acorn Engineering parts only. Please order through your local representative or distributor. The phone number to locate your local representative is 1.800.591.9360. ACORN ENGINEERING FIELD SERVICE TOLL FREE 800-743-8259 •...
  • Page 11 7001-202-199 SENSOR SPACER 0711-407-199 POWER SUPPLY, 240VAC/9VDC 7003-028-199 TRANSFORMER BRACKET Repairs must be made with Acorn Engineering parts only. Please order through your local representative or distributor. The phone number to locate your local representative is 1.800.591.9360. ACORN ENGINEERING FIELD SERVICE TOLL FREE 800-743-8259 •...