TROUBLE
FILTER MOTOR
FAILS TO START
FILTER DOESN'T
CLEAN POOL
FILTER DOESN'T
PUMP WATER OR
FLOW IS VERY
SLOW
PUMP DOESN'T
WORK
TOP COVER
LEAKING
HOSE LEAKING
AIR LOCK
• To facilitate the connection of the hoses into the black protruding hose
connectors on the liner, you may use soapy water solution (mix 6 drops of dish
washing liquid in 1/2 a cup of water) to lubricate the hoses and the black
protruding hose connectors. Continue per owner's manual.
• Do not use lubricants such as machine or industrial oil or grease.
SAVE THESE INSTRUCTIONS

TROUBLESHOOTING GUIDE

CAUSE
• The motor is not plugged in.
• The fuse box needs checking.
• The GFCI/RCD circuit breaker
is tripped.
• Motor too hot and overload
protection is shut off.
• Improper chlorine or pH
levels.
• Filter cartridge is dirty.
• Damaged cartridge.
• Excessively dirty pool.
• The strainer screen is
restricting the water flow.
• Clogged inlet or discharge.
• An air leak on the intake line.
• Scale or buildup on cartridge.
• Excessively dirty pool.
• Dirty filter cartridge.
• Nozzle and strainer
connection are reversed.
• Low water level.
• Strainer screen plugged up.
• An air leak on the intake hose.
• Faulty motor or the impeller
is jammed.
• An air lock inside the
cartridge chamber.
• O-ring missing.
• Cover is not tight.
• Filter cartridge is dirty.
• Hose clamps are not
well-fitted.
• There's air trapped in the
pump housing and inlet hose.
(58) MODEL 604 FILTER PUMP ENGLISH 7.5" X 10.3" PANTONE 295U 06/08/2009
SOLUTION
• Filter cord must be plugged into a 3
wire outlet that is protected by a Class
A Ground Fault Circuit Interrupter, or
RCD.
• Reset circuit breaker. If circuit breaker
trips repeatedly, your electrical system
may have a defect. Turn off circuit
breaker and call an electrician to
correct the problem.
• Let the motor cool down.
• Adjust the chlorine and pH level. Consult
your local swimming pool supply stores.
• Clean or replace cartridge.
• Check the cartridge for holes. Replace
if damaged.
• Operate the filter for longer periods.
• Clean the strainer screen at the inlet.
• Clear any obstructions in the intake
hose by discharging it inside pool wall.
• Tighten hose clamps, check hoses for
damage, check pool water level.
• Replace cartridge.
• Clean cartridge more often.
• Install the nozzle at the upper position
of the pool inlet, and the strainer at the
lower position of the pool outlet.
• Fill pool to correct water level.
• Clean strainer screens at pool inlet.
• Tighten hose clamps, check hose for
damage.
• Clear any sticks or leaves in the
intake hose.
• Open the release valve at top of pump.
• Remove cover & check for O-ring.
• Tighten cover (Manually).
• Replace or clean cartridge.
• Tighten or change hose clamps.
• Open air release valve, lift and lower
the inlet hose until water starts to flow
out of the air release valve, close air
release valve.