ALARM SIGNALS

Alarm signals;
Message
Cause
EE
Date or memory failure
P1
Probe failure
HA
Max. temp. alarm
LA
Min. temp. alarm

ALARM RECOVERY

Probe alarm "P1" starts some seconds after
the fault in the related probe; it automati-
cally stops some seconds after the probe
restarts normal operation. Check connec-
tions before replacing the probe.
Temperature alarms "HA" and "LA" auto-
matically stop as soon as the thermostat
temperature returns to normal values and
when defrost starts.
Alarms "EA" and "CA" (with i1F=bAL) re-
cover as soon as the digital input is
disabled.
Alarm "CA" (with i1F=PAL) recovers only by
switching off and on the instrument.

TECHNICAL DATA

Housing: self extinguishing ABS.
Case: XR30C frontal 32x74 mm; depth 60mm;
Mounting: XR30C panel mounting in a
71x29mm panel cut-out
Protection: IP20.
Frontal protection: IP65 with frontal gasket
RG-C (optional).
Connections: Screw terminal block ≤ 2,5
mm2 wiring.
Power supply: according to the model:
12Vac/dc, ±10%; 24Vac/dc, ±10%;
230Vac ±10%, 50/60Hz, 110Vac ±10%,
50/60Hz
Power absorption: 3VA max
Display: 3 digits, red LED, 14,2 mm high.
Inputs: 1 NTC or PTC probe.
Digital input: free contact
Relay outputs:
compressor: SPST relay 8(3) A, 250Vac or
SPST relay 20(8)A; 250Vac
second relay: SPDT relay 8(3) A, 250Vac or
Data storing: on the non-volatile memory
(EEPROM).
Kind of action: 1B; Pollution grade: normal;
Software class: A.
Operating temperature: 0÷60 °C.
Storage temperature: -30÷85 °C.
Relative humidity: 20÷85% (no condensing)
Measuring and regulation range:
NTC probe: -40÷110°C (-40÷230°F)
PTC probe: -50÷150°C (-58÷302°F)
Resolution: 0,1 °C or 1°C or 1 °F (selectable).
Accuracy (ambient temp. 25°C): ±0,7 °C ±1
CONNECTIONS
XR30C: 8A compressor
11