(4) Camera signal system adjustment mode
In the camera signal system adjustment mode, the auto white balance function is stopped in order to adjust the camera. In this
mode, the white balance is set to the indoor mode and focussing is performed manually.
1) How to enter the camera signal system adjustment mode
Set the data value at address "0000" to "
]
The camera signal system adjustment mode will be established.
*When the camera signal system adjustment mode is established, make adjustment according to "(5) Camera adjusting
procedure".
2) How to enter the normal mode
Set the data value at address "0000" to "
]
The normal mode will be established.
]
Pressing "CONTINUE" key will make the display "CAM ADJ" disappear and make it possible to perform normal operation.
(5) Camera adjusting procedure
1. Adjustment of auto focus
2. Basic adjustment of iris and ND meter
3. Adjustment of black balance/Adjustment of A/F noise
4. Rough adjustment of iris AE
5. Rough adjustment of white balance
* "1. Adjustment of auto focus" is performed in the auto focus adjustment mode. The other adjustments are performed in the camera
signal system adjustment mode.
00".
FF".
6. Rough adjustment of color gain
7. Adjustment of white balance
8. Adjustment of color gain
9. Adjustment of auto white balance adjustment
10. Adjustment of iris AE
43