I_trip error, PFC over current
Indoor display
Outdoor display
1.Checklist :
1) Is the PFC Shunt(A*V18***:R062,R063,A*V24***:R807,R808,R809) resistance value correct? Check the resistor is opened
2) Is the condition of surrounding temperature abnormal overload?
3) Is there any problem as like the temperature sensor separation or measurement value error?
4) Is the interphase resistance of compressor normal?
2. Troubleshooting procedure
Restart a er power o .
Is the condi on of indoor/outdoor
temperature normal load?
YES
Is the posi on of temperature
sensor and the sensing value
normal?
YES
Is the connec on cable for the
compressor and power terminal
normal?
YES
Exchange the Outdoor PBA
12-18
Outdoor error
I_trip error, PFC over current
NO
YES
NO
NO
Restart a er returning to the normal load
NO
Is the I_trip error
Terminate the
occurred again?
service
Correct the sensor posi on or exchange the sensor
Correct the cable connec on