CAUTION: For continued safety, replace safety critical components only with manufacturer's recommended parts (refer to parts list).
ponents. For continued protection against risk of fire, replace only with same type and rating fuse(s). To reduce the risk of electric shock, leakage-current or resis-
tance measurements shall be carried out (exposed parts are acceptably insulated from the supply circuit) before the appliance is returned to the customer.
DN
DO
D55
+B
R219
D57
100K
FL2
R221
D59
100K
H.P
L1
RELAY
DRIVER
R229
22 1/4W
2.8V
Q354
12
FL1
R223 47K
R362
270
R225
1/4W
D61
33K
+B
B
C251
C253
SP. A
D56
0.22
0.22
RELAY
DRIVER
C255 0.1
+B
Q351
C256 0.1
R220
FR2
D58
11
100K
C252
C254
0.22
0.22
R356
R222
SP. A
D60
270
100K
ON: 2.8V
1/4W
+B
L2
R230
SP. B
22 1/4W
ON: 2.8V
R224 47K
Q352
FR1
D62
R226
14
33K
R357
270
1/4W
SP. B
+B
RELAY
28.0V
B
DRIVER
D93
+B
Q353
R310
D94
SL/SRch/Cch
100K
C2
RELAY DRIVER
R311
100K
D95
C259
C261
0.22
0.22
L5
Q353
C263 0.1
R315
22 1/4W
10
C264 0.1
R312 47K
C260
C262
R358
C1
D96
Cch/Surr
270
R313
0.22
0.22
: 2.8V
1/4W
33K
C269
C270
B
0.22
0.22
C271 0.1
R359
270
1/4W
D75
+B
R269
D77
LS2
100K
R451
R279
22 1/4W
1 1/4W
L3
Q421
59.0V
12.5V
+B
R271
Q423
56.9V
D79
100K
57.6V
R455
R273 47K
390
LS1
Q427
D81
R275
1/4W
33K
B
Q421,422
Q428
POWER
LIMITTER
D76
Q423,424
CONT.
LIMITTER
C354
R456
+B
ON/OFF CONT.
47u100
W57
390
(SURR.MODE : ON)
+
1/4W
R270
RS2
D78
100K
R280
Q424
Q422
22 1/4W
-56.6V
-12.4V
L4
R272
D80
100K
R274 47K
RS1
+B
D82
R276
33K
-59.0V
B
B
x
a o
y
B
.
i
+17V
DP
DQ
CN1
FL1
10
FL
FL2
9
FR1
8
FR
FR2
7
+B
C1
6
C
+B
C2
5
59.4V
LS1
4
SL
LS2
3
RS1
2
SR
RS2
1
K5
R384
8.2K
CN8
1
R361
2
1
470 2W
3
J1
+B
FAN
Lch
ON/OFF
K1
CONT.
SP A
25
Rch
28.0V
24
Lch
K2
SP B
Rch
+B
R392
100K
WH13-1 (1/2)
BLK
13
WH10-1 (1/2)
BRN
10
R393
WH17-1 (1/2)
WHT
17
100K
WH16-1 (1/2) GRY
16
B
WH3
R394
4
10
1 SLch
B
K3
1/4W
-56.6V
Q
Q
3
2
GND
3
7
6
R398
2
17.1V
2
2.7K
3
SRch
1/4W
1
4
Cch
K4
28.0V
+B
+B
+17V
C308
D213
D215
11.9V
47u100
+
D201
D121 D122
D203
C307
Q425
10u100
W50
+
-35.0V
Q427,428
SURROUND or
LIMITTER
C306 10u100
STEREO MODE
ON/OFF CONT.
+
DISCRIMINATION
(ST MODE : ON)
D123
Q429
ST MODE : ON
SURR.MODE : OFF
-3.6V
D204
Q426
D202
R458
2K
D216
D214
11.9V
+B
B
u 1 6 3
indicates safety critical com-
DR
DS
2
4
8
9
9
D107
CURRENT
PROTECTION
D108
Q383
Q384
Q381
Q382
E2
D105
VOLTAGE
PROTECTION
21
FAN
FAN DRIVER
CN6
WH5
Q404
M
+B
1
1
1
R510
2
2
2
1.8K 2W
3
3
3
Q402
Q401
Q403
FAN
THERMISTOR
CN7
H/L CONT.
2
2
19
1
1
59.0V
C405
0.01
WH12-1 (1/2)
WHT
D100
C406
0.01
WH11-1 (1/2)
(X07-) (B/5)
YEL
D102
D101
WH14-2 (2/2)
C401
WH16-2
24000u75
WH14-1 (1/2)
RED
(2/2)
+
WH15-1 (1/2)
GRY
WH15-2 (2/2)
WH17-2
C402
3
1
5
1
5
0
8
9
YEL
24000u75
(2/2)
+
WHT
VR-5700/5900 ONLY
R401
33K
(X35-2260-12) (B/2)
Q406
Q405
R402
10K
R158
1K 1/4W
E3
CN5
NC
WH4
3
3
FAN +B
+B
+B
2
2
RELAY GND
1
1
CN4
25
25
FAN ON/OFF
-56.6V
B
24
24
FAN H/L
23
1W
22
10W
R395
21
21
I. PROTECT
6.8K
20
20
V. PROTECT
1/4W
19
19
THERM SW
-35V
18
F. OFF
AVR
Q407
+12V
17
uCOM +12V
-34.5V
16
uCOM GND
15
RELAY POWER
D124
AZ-1
14
14
RELAY B
I
13
G GND
12
12
RELAY H.P
11
11
RELAY A
10
10
RELAY CS
+B
9
FAN +B
8
RELAY GND
35V
7
-35V
6
RELAY TR
5
5
SP B/S-MUTE
4
4
F/C/SW-MUTE
3
3
PRE S-MUTE
2
2
PRE ZB-MUTE
1
1
OUTPUT-MUTE
m
R396
10K
E1
c o
1
uCOM GND
POWER
14.9V
Q408
WH2
+12V
2
uCOM +12V
RELAY
DRIVER
3
F. OFF
.
4
RELAY POWER
The DC voltage is an actual reading measured with a high impedance type voltmeter with a cassette loaded at
playback mode. The measurement value may vary depending on the measuring instruments used or on the
product. Bias circuit DC voltage is measured while in the record mode.