1. Communication Specifications
Communication specification for this unit are as follows:
Baud Rate
Data Length
Parity
Stop Bit
Flow Control
2. Command Format
2-1. Command data format
When sending a control command to this unit, use the following data format:
Header
Header
ID
SP
CR
2-2. Response data format
Upon executing a control command it has received, this unit sends back the following response data to the com-
puter:
Header
Header
ID
SP
Normal Termination Status : 0 (30h)
CR
2-3. Parameters used for the data format
The following 3 types of parameters are used for command and response data:
1 Numeric value 2 ON/OFF 3 Special parameters
Each parameter is as follows:
1 Numeric value
A 2-byte hexadecimal value (sign included) is represented by a set of 4-digit (4-byte) characters.
Assignable range: 8000H to 7FFFH
2 ON/OFF
Shows the status (ON or OFF) of the unit, such as POWER and HIDE.
Character
36
9600/19200 bps
8 bit
None
1 bit
None
[
ID
Command
SP
: Designates the head of data and the data type.
! (21h): Assigns command to the projector
? (3Fh): Query to the projector (Asking command)
:1: Identification number of the projector (Factory setting is 1)
: Designates the delimiter for ID, Command and Parameter. (20h)
: Designates the terminal of the data. (0Dh)
*[ ] is not necessary for Asking command.
ID
SP
Normal Termination Status
: Designates the head of the data.
@ (40h): Fetches data from the projector
: 1: Identification number of the projector (Factory setting is 1)
: Designates the delimiter for ID, Command and Parameter. (20h)
: Designates the terminal of the data. (0Dh)
Hex
Meaning
0
30
OFF
1
31
ON
[
SP
Parameter
CR
[
SP
Parameter
[
CR