LG LWC183MGMJ1 Service Manual page 16

Room air conditioner
Table of Contents

Advertisement

ELECTRIC PARTS TROUBLESHOOTING GUIDE:
MODEL: LWC183MGMJ1, LWC183MSMM1
Possible Trouble 1
Is the Trans output power the
same as specified?
YES
Is the Trans output power
about AC 14V?
YES
Is output Voltage of IC01D
DC 12V?
YES
Is output Voltage of IC02D
DC 5V?
YES
Is the reset circuit all right?
(The No.14 of Micom
is 5V.)
YES
Is the
connection between
Main and Display
all right?
YES
Is the voltage No.18 of Micom
DC 5V?
YES
Exchange Main P.W.B Ass'y.
• The unit does not operate.
NO
NO
Is shorted the Trans. output?
NO
NO
NO
NO
NO
—16—
NO
YES
• Check the Fuse.
• Check the wiring diagram.
• Check the Main
P.W.B pattern.
• Exchange the Trans.
Exchange D02D~D05D.
• Exchange IC01D.
• Exchange IC02D.
• Exchange IC01A.
• Connect connector
exactly.
• Check the P.W.B
pattern.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lwc183msmm1Lwc183mgab1

Table of Contents