Single Line (Gravity Feed System) - Riello 40 F10 Installation & Operating Manual

Single stage operation oil burner with manual air shutter
Table of Contents

Advertisement

Riello manometers and vacuum gauges do not require any adaptors, and can be safely
connected to the pump ports. An NPT (metric) adapter must be used when connecting
other gauge models.
2
1
3

SINGLE LINE (GRAVITY FEED SYSTEM)

A) The burner is shipped configured for use in single line applications. No changes to
the oil pump are required for use in single line applications.
NOTE: If the pump cover (1) is removed for any reason, be sure the O-ring (2), is properly
seated in the pump cover (1) before re-attaching the pump cover to the pump housing.
SINGLE LINE SYSTEM - PIPE LENGTHS
H
3/8" OD
FT
M
FT
1.5
0.5
33
3.0
1.0
65
5.0
1.5
130
6.5
2.0
195
NOTE: Do not exceed pipe lengths
indicated in chart.
B) Connect the pipe connector to the SUPPLY PORT (6) of the pump. Attach the required
piping to this pipe connector. Be sure that the plug in the RETURN PORT (9) is tightened
securely.
6
5
4
1/2" OD
M
FT
M
10
65
20
20
130
40
40
260
80
60
325
100
F10 - 9
9
D6009
8
4
D6179

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents