SETTING
TC FORMAT
Follows the DF/NDF of the time code from the camcorder
connected to this unit.
• AUTO ....... Follows the time code format of the camcorder.
• NDF ........... Records the time code in NDF format.
• DF .............. Records the time code in DF format.
Notes
The default [AUTO] setting is NDF. If time code information
from the camcorder is not obtained, this unit is set to the most
recent recording setting.
DV FILE TYPE
Changes the DV recording format.
• AVI ............ Records video in AVI format.
• RAW DV ... Records video in DV format.
INTERVAL
• REC TIME
Selects the interval recording time.
You can select [0.5sec], [1sec], [1.5sec] or [2sec].
• INT.TIME
Selects the interval time between recordings.
You can select [30 sec], [1 min], [5 min], or [10 min].
CAM LINK SEL
When CAM LINK is set to [ON], select the type of camcorder-
linked operation.
• FOLLOW ...... Uses this setting when connecting to a
camcorder that has no "external REC
control" function. The unit follows the
camcorder operation.
• SYNCHRO ... Uses this setting when connecting to a
camcorder that has an "external REC
control" function. The unit operates
simultaneously with the camcorder.
SLEEP MODE
Switches the sleep mode ON/OFF.
• OFF
Sleep mode is set to OFF.
• 1min
If the i.LINK cable is disconnected and no operation is done
for more than one minute, this unit automatically switches to
SLEEP status.
• 5min
If the i.LINK cable is disconnected and no operation is done
for more than five minutes, this unit automatically switches
to SLEEP status.
To return to normal status, reconnect the i.LINK cable to this
unit or turn the POWER switch off and back on.
Notes
In SLEEP MODE, this unit is not completely switched off but
continues to run using low power consumption.
8
CAMERA NO
You can assign a number to the data clip name when
recording.
Use this mode to assign non-overlapping numbers to clip
names recorded simultaneously on more than one camcorder,
or to manage clip data by assigning numbers.
Press the PREVIOUS/REW (previous clip/rewind) or NEXT/
FF (next clip/fast-forward) button to select the number and
press the PLAY/EXEC (playback/execute) button.
Select the digits one by one. The display returns to the menu
after two digits are selected.
The factory default setting is [00].
ALL RESET
Restores all default settings.