Install or replace the 3-1.5 Volt AA batteries in the battery
compartment. When necessary, always replace all three
batteries at once to ensure normal operation of the keypad
over the anticipated battery lifetime. Make sure that battery
positive (+) and negative (–) terminals are properly oriented
with the battery spring clip connections. Refer to battery
placement graphic below.
AA BATTERY
AA BATTERY
AA BATTERY
Battery Compartment
Reattach the keypad to its mounting plate by aligning the
four mounting holes in the keypad case back with the four
mounting clips on the mounting plate. Lower the keypad
onto the clips.
Anticipated battery life is 1.5 years.

PROGRAMMING

The following two items must be programmed into the
keypad by the installer.
House ID Code (Step 1 in Installer Programming mode)*
System Type (Step 2 in Installer Programming mode)
*The same House ID Code must also be programmed in the
control panel.
Programming a different House ID will
disable communication.
Installer Programming
Enter the program mode by pressing the [1] and [3] keys
simultaneously for five (5) seconds.
The DISPLAY alternately flashes small 00 and two dashes
(--).
NOTES:
Entering a value other than one specified in the
following steps may cause unpredictable results.
If the unit times out before you have pressed the star
(✴) key to save a programmed value, you will need to re-
enter the Programming mode and reprogram the option.
STEP
ACTION
1.
Press [1] (House ID Code)
(10 = default)
Enter the two-digit house code (01-31)
Press [✱] to continue.
2.
Press [2] (System Type).
Press (1) for VISTA or (2) for LYNX
(2 = default)
Press [✱] to continue.
3.
4.
(5828V
only)
5.
6.
7.
Exiting Programming Mode
You can exit programming mode by pressing the [✱] key
whenever the small 00 and (- -) are alternately displayed.
Programming or Changing a User Code (Required if
using Quick Arm function on Lynx or VISTA)
Enter user program mode by pressing the [7] and [9] keys at
the same time until the display flashes double dashes (- -).
Enter the desired 4-digit user code that matches a user code
programmed in the control panel. There will be no display
of the user code entered.
Press the [✱] key to place the 4-digit code in memory and
exit the user program mode.

SPECIAL FUNCTION KEYS

As shown in the figures on page 1, each keypad contains four
Special Function keys (A, B, C, D) that may be programmed
to execute the commands shown below.
NOTE: The Function Key Select setting in Step 6 of the
INSTALLER PROGRAMMING procedure above, determines
the operation of the Special Function keys A, B, C, and D as
follows:
DISPLAY
If you select "0"
Alternately
flashes "t1"
Function Key
and the 2-
A
digit house
B
code.
C
Alternately
flashes "t2"
D
and 2
NOTE: Do NOT use the 5828V for silent panic operation
because the keypad itself is not silent.
-
2 -
Press [3] (Exit Delay)
Press 0-9 in 15 second increments.
Example: If you press 3, exit delay
would be 3 times 15 seconds for a total
of 45 seconds.
NOTE: The Exit Delay programmed
here should match the Exit Delay
programmed in the control panel.
(0 = default)
Press [✱] to continue.
Press [4] (Voice enable/disable).
Press (0) to disable.
Press (1) to enable.
(1 = default)
Press [✱] to continue.
Press [5] (Wireless Protocol).
Press [1] for LYNX models
Press [2] for LYNXR, LYNXREN, or
VISTA
(2 = default)
Press [✱] to continue.
Press [6] (Function Key Select).
Press [0] for Panic Key
Press [1] for Single-button arming
NOTE: The programming here should
match the programming of the control
panel to simplify end user operation.
(1 = default.)
Press [✱] to continue.
Press [7] (Restore Defaults).
Press [1] to restore factory settings.
Press [✱].
Exit programming mode.
Function
[1] + [✱]
[✱] + [#]
[3] + [#]
(Not used for panic alarms)
Alternately
flashes "t3"
and value
selected.
Alternately
flashes "t4"
and (0 or 1)
Alternately
flashes "t5"
and (1 or 2)
Alternately
flashes "t6"
and (0 or 1)
Displays
"EE"
Message Sent
to Control
(Alarm zone 95)
(Alarm zone 99)
(Alarm zone 96)

Hide quick links:

Advertisement

loading

This manual is also suitable for:

Ademco5828vAdemco 5828v