Download Print this page
Honeywell 5828 Installation And Setup Manual
Honeywell 5828 Installation And Setup Manual

Honeywell 5828 Installation And Setup Manual

Installation guide

Advertisement

Quick Links

GENERAL INFORMATION
The ADEMCO 6148 is an addressable remote keypad
designed for use with ADEMCO control panels. Addresses
are set via the keypad keys.
The keys on the keypads are continuously backlit for
convenience.
KEYPAD DISPLAY AND LEDS
The ADEMCO 6148 keypad has a fixed-word display and a 2-
digit zone identifier.
The following table describes the LEDs and their functions:
LED
Function
Red (ARMED)
Lights when the system is armed in any mode.
Green (READY)
Lights when the system is "ready" to be armed.
SPECIAL-FUNCTION KEY PAIRS
The keypad also features special-function key pairs. These
key pairs may be used to activate panic alarms. See the
control's instructions for details.
Key pairs activate immediately.
The following key pairs are used by the ADEMCO 6148 to
manually activate silent emergency, audible emergency,
personal emergency, or fire alarms:
[1] & [✱]
[✱] & [#]
[3] & [#]
WIRING AND INSTALLATION
The keypads can be surface mounted directly to a wall, or to
a single- or double-gang electrical box.
1.
Remove the case back by pushing down two "snaps."
See diagram that follows.
2.
Route wiring from the control panel through the
opening in the case back.
3.
Mount the case back to a wall or electrical box.
4.
Wire directly from the keypad's terminal block to
the terminal block on the control board.
Table that follows.
Wiring Table
Keypad
Control Panel
Î G
Data In
– Aux Pwr (GND)
+
+ Aux. Pwr
Ï Y
Data Out
5.
Reattach the keypad to its case back.
INSTALLATION AND SETUP GUIDE
See Wirng
Wire Color
Green
Black
Red
Yellow
NOTE:
TO REMOVE CASE BACK
PUSH IN THE TWO MOUNTING
SNAPS LOCATED ALONG THE
BOTTOM OF THE KEYPAD
AND LIFT UP.
RETAINING
SNAPS
SETTING THE KEYPAD ADDRESS
The keypad can be set either for an address of 00-30, or to the
non-addressable mode (31). The keypad's default address is 31.
Refer to the Installation and Setup Guide of the
control panel being used for correct address
settings and other details.
To change the keypad's address, do the following:
1. Power up the keypad. Within 60 seconds of power-up, press
and hold down the [1] and [3] keys at the same time for 3
seconds. (If unable to enter address mode, power up and try
again.)
The current keypad address is displayed, and the cursor is
under the "tens" digit. If 10 seconds have passed with no
key entry, the keypad automatically exits address mode.
You must power down, power up and start address mode
again.
NOTE: The keypad will not enter address mode if the panel
to which it is connected is in programming mode.
2. Set the current address to "00": Press [0] to clear the
current "tens" digit. The cursor moves to the "ones" digit
position. Press [0] to clear the current "ones" digit. The
cursor moves back to the "tens" digit position.
3. Enter the keypad's address: Enter the proper "tens" digit of
the keypad's address. The cursor moves to the "ones" digit
position.
Enter the proper "ones" digit of the keypad's
address. Note that address "31" sets the keypad to non-
addressable mode.
4. Exit address mode: Press [✱] to save the displayed address
and exit address mode.
VIEWING THE KEYPAD ADDRESS
Press and hold down the [1] and [3] keys at the same time for
about 3 seconds. The current address is displayed. No key
entry is allowed. Press any key to exit, or wait 10 seconds to
automatically exit viewing mode.
K5320V2 4/04 Rev. A
ADEMCO 6148
Remote Keypad

Advertisement

loading

Summary of Contents for Honeywell 5828

  • Page 1 K5320V2 4/04 Rev. A ADEMCO 6148 Remote Keypad INSTALLATION AND SETUP GUIDE GENERAL INFORMATION The ADEMCO 6148 is an addressable remote keypad designed for use with ADEMCO control panels. Addresses are set via the keypad keys. The keys on the keypads are continuously backlit for convenience.
  • Page 2 REFER TO INSTALLATION INSTRUCTIONS FOR THE CONTROL PANEL WITH WHICH THIS DEVICE IS USED FOR WARRANTY INFORMATION AND LIMITATIONS OF THE ENTIRE ALARM SYSTEM. 165 Eileen Way, Syosset, New York 11791 Copyright © 2004 Honeywell International Inc. www.honeywell.com/security ÊN5320V14Š K5320V2 4/04 Rev. A...

This manual is also suitable for:

Ademco 6148