Section 4: Electrical Hook-Up; Section 6: Operation - Digi II series Installation & Operation Instructions

Digi ii series heater
Table of Contents

Advertisement

"Digi II" Series Heater Installation & Operation Instructions

SECTION 4: ELECTRICAL HOOK-UP

Electrical installation must be made by a licensed electrician in
accordance with the National Electrical Code and local regulations.
Remove the painted cover from the side of the heater . Route the feed
wires through the holes provided in the bo ttom of the heater and
connect the wires to the appropriate labeled wires. To determine the
correct wire size, refer to Diagram 4. Use copper supply wire only,
suitable for minimum 90 degrees C. The heater must be grounded! See
Diagram 5 for proper connections.
SECTION 5: HEATER SCREEN (GUARD RAIL)
Install a wooden heater guard to prevent the sauna bather from
accidentally touching the sauna heater. Install the heater guard rail
with the height clearances and dimensions shown in Diagram 7.

SECTION 6: OPERATION

The control for this heater has a thermostat to adjust the sauna
temperature and a timer to control when the heater starts and stops. The
maximum the timer will allow the heater to operate is 60 minutes. For
health and fire safety, never attempt to alter or bypass the timer or
thermostat.
The Digi II (1601-11) Control should be mounted outside the room.
The control has 16ft control wire supplied. The maximum control wire
length would be 90ft.
The sensor should be mounted over the heater 2" from the ceiling and
connected to the circuit board on terminals 2 and 3. See Diagram 1
Control Overview
Alarms The control is equipped with an alarm that indicates a faulty
thermostat sensor and or wire. The control will display "heat sensor
cable cut". During the alarm the control will turn power off to the
heater and the display will remain on the control. Rectify the fault
situation and recycle power to heater. If problem persists refer to
Section 13.
Locking Key Pad The control keypad can be locked. With the control
in the Off mode, press the up arrow key and then press the down arrow
key. "Locked" will be displayed. This will make all key inactive until
the control is unlocked.
WARNING
Do not locate benches over
heater. Minimum clearance
of ceiling above heater 45".
For minimum clearance
from heater to wooden
surfaces refer to Diagram 1
for distances. The mounting
brackets supplied provide
the proper clearance from
the heater to the wall.
Use only copper wire of the
size and type indicated in
the Heater Specification
Chart and the temperature
rating indicated on the
heater junction box.
All heaters and controls
must be grounded per NEC
to prevent electrical shock
in case of unit failure.
Electrical outlets or
receptacle must not be
installed in a sauna room.
A guardrail or fence is
required around the heater
to prevent burns from
accidental contact.