Read all instructions carefully before installation. Please
leave all instructions and warranty with the owner.
WARNING
Prolonged exposure to elevated temperatures is capable of inducing
hyperthermia. Hyperthermia occurs when the internal temperature of
the body reaches several degrees above the normal body temperature
of 98.6°F. The symptoms of hyperthermia include an increase in the
normal temperature of the body, dizziness, lethargy, drowsiness, an d
fainting. The effects of the hyperthermia include failure to perceive
heat, failure to recognize the need to exit the room, unawareness of
impending hazard, fetal damage in pregnant women, physical inability
to exit the room and unconsciousness.
WARNING
The use of alcohol, drugs, or medication is capable of greatly
increasing the risk of fatal hyperthermia.

SECTION 1: GENERAL INFORMATION

These heaters are UL approved for permanent installations and
electrical connections.
conducting parts are protected against water. All wiring must be
performed in accordance with local codes. See Diagram 4 for wire and
room size requirements.
These heaters are wall mounted, 18¾" W x 11" D x 24¼" H, with wall
mounted controls.
Built with splash proof construction, the
WARNING
Do not take a sauna if using
alcohol, drugs or
medications.
Pregnant women or persons
with poor health should
consult their physician
before using any sauna.
Caution fire hazard: Do not
use the sauna room for
drying clothes, bathing
suits, etc. Do not hang
towels above heater or place
any object other than the
rocks supplied on the
heater. If any darkening of
the wall around the heater
is noticed discontinue sauna
use immediately.
Inspect sauna regularly for
required maintenance to
heater, control and benches.
Replace wood surfaces
which show any signs of
deterioration.
The heater gets extremely
hot during operation and
should not be touched or
burns may result.
Minors should be
adequately supervised
whenever near a hot or
warming sauna.

Advertisement

Table of Contents
loading

Summary of Contents for Digi Digi II series

  • Page 1: Section 1: General Information

    "Digi II" Series Heater Installation & Operation Instructions WARNING Do not take a sauna if using alcohol, drugs or medications. Pregnant women or persons with poor health should consult their physician before using any sauna. Caution fire hazard: Do not...
  • Page 2 "Digi II" Series Heater Installation & Operation Instructions DIAGRAM 1 MOUNTING BRACKET LOCATION AND MINIMUM DISTANCE TO COMBUSTIBLE MATERIAL Use the long screws in the upper holes of the mounting bracket Screws 11" " Screws 11" Table 1 Temperature 2"...
  • Page 3 "Digi II" Series Heater Installation & Operation Instructions WARNING SECTION 2: MOUNTING OF SAUNA HEATER HANGING THE HEATER Using the template provided, drill four Fire sprinkler systems used 9/64" holes to fasten the heater brackets to the wall. Install two ¼" x 1 inside any sauna room ½"...
  • Page 4 "Digi II" Series Heater Installation & Operation Instructions DIAGRAM 2 DIAGRAM 3 DIAGRAM 4 MINIMUM ROOM MAXIMUM ROOM WIRE HEATER MODEL Ceiling Volume Ceiling Volume SUPPLY TO Product Number Floor Area Height Cu. Ft. Height Cu. Ft. PHASE VAC AMPS...
  • Page 5: Section 4: Electrical Hook-Up

    Electrical outlets or The Digi II (1601-11) Control should be mounted outside the room. receptacle must not be The control has 16ft control wire supplied. The maximum control wire installed in a sauna room.
  • Page 6 "Digi II" Series Heater Installation & Operation Instructions DIAGRAM 5 354 SKSO 25 F Heater Input Heating elements 208V or 240V SEPC 93 SEPC 94 SEPC 95 1500W 2000W 2670W Type 1714 - 450 - 1705 240V 208V 1,2,3 1714 - 600 - 1705...
  • Page 7: Control Setup

    "Digi II" Series Heater Installation & Operation Instructions SECTION 6: OPERATION, CONTINUED Increase On/Off Temperature Memory / User 1 Delayed Start Time Sauna Length Memory / User 2 Light Memory / User 3 Memory / User 4 Decrease Control Setup: This setup has 6 different menus.
  • Page 8 "Digi II" Series Heater Installation & Operation Instructions SECTION 6: OPERATION, CONTINUED Next will display: MENU 3 OFFSET: T1 0C Using the arrow keys, select the calibration value (0 +/-10C). Example: After reading the temperature on the thermometer in the sauna, you noticed that the temperature reading in the display is 4C higher.
  • Page 9 "Digi II" Series Heater Installation & Operation Instructions SECTION 6: OPERATION, CONTINUED Programming Memory (User buttons) continued... Press the TEMPERATURE button and the temperature value will appear in the display current temperature setting: The temperature can now be set using the arrow keys. When the desired temperature has been selected, press PROG/OK and the display will return to the previous screen.
  • Page 10 "Digi II" Series Heater Installation & Operation Instructions SECTION 6: OPERATION, CONTINUED Setting Time Delay with Saunasmart: Saunasmart means choosing the time to enter the hot room, not the time to turn the heater on. The system will calculate when to turn on in relation to entry time. The control will be able to determine how long the system needs to run to reach set temperature.
  • Page 11 "Digi II" Series Heater Installation & Operation Instructions SECTION 7: HIGH LIMIT CONTROL (RESET BUTTON) The sauna heater has a built-in high limit control, which automatically turns off the heater if the temperature inside in the sauna room rises to an abnormally high level.
  • Page 12 "Digi II" Series Heater Installation & Operation Instructions DIAGRAM 6 DIAGRAM 7 TYPICAL PRE-CUT WALL CONSTRUCTION HEATER SCREEN (GUARD RAIL) min 1 ½ " 1/2" wallboard 2x4" framing fiberglass insulation min 1 ½ " foil vapor barrier min 1" T&G soft wood...
  • Page 13 "Digi II" Series Heater Installation & Operation Instructions WARNING SECTION 9: WARNING PLACARDS Two metal placards are included in the Installation Instruction The "CAUTION" and Envelope packaged with every Sauna Heater. The CAUTION placard "WARNING" placards must be attached to the interior wall of the sauna room directly above must be mounted in the heater where it is visible to the bather.
  • Page 14: Section 11: Ventilation

    "Digi II" Series Heater Installation & Operation Instructions SECTION 11: VENTILATION VENTILATION should be changed about 6 times an hour. This can be achieved by making a vent opening (fresh air inlet) in the sauna wall directly below the heater. The air outlet must be lower than the upper benches, as far as possible from the heater and about two feet higher than the fresh air inlet vent, See Diagram 8.

This manual is also suitable for:

Digi ii 8.0Digi ii 6.0Digi ii 4.5

Table of Contents