1-2. ERROR DETECTION MONITOR
Device acknowledge is used to check IIC errors. Device acknowledge is checked by sending an IIC start sequence during CRT power
on. Each device is checked three times, if there is no acknowledge after every attempt, it will be regarded as an error.
There are three step to check errors.
1. IIC line 0
If all devices except the NVM have errors, IIC line 0 error is displayed.
2. Board check
If all devices mounted on one board have errors, board error is displayed.
3. Each device check
if IIC line error and board error are not detected then the device with an error is displayed.
The detected errors can be displayed as follows:
1. Error Monitor Menu
2. Error Reader
1-2-1. Error Monitor Menu
The error monitor menu is displayed by selecting TT33. The following menu will be displayed:
Error Monitor
1
Ignore Errors
OFF
Operating Time :
000021 h 40 min
Stored Errors :
1. A-Board
2. B3-B CXA2100 MID
3. J-B CXA2123 Main Col Dec
4. Error Code Not Valid
5. Error Code Not Valid
Current Error :
Start Error Sequence
– 5 –
KP- 48PS1/53PS1/61PS1
48PS1K/53PS1K/61PS1K
ON
ON
K
RM-892