Mitsubishi Electric PUG18AK Technical Manual page 13

Split-type,heat pump air conditioners pug & pugh condensing units
Table of Contents

Advertisement

4
PERFORMANCE DATA – OPERATING PRESSURES
PL/H18FK
with
Indoor
Cooling
Wet Bulb Capacity
EER
(°F)
(Btu/Hr)
63
18,288
13.85
65
18,864
14.03
67
19,944
14.61
69
20,214
14.48
71
20,988
14.78
Indoor
Cooling
Wet Bulb Capacity
EER
(°F)
(Btu/Hr)
63
17,604
11.66
65
18,162
11.86
67
18,720
12.05
69
19,476
12.29
71
20,214
12.50
Indoor
Cooling
Wet Bulb Capacity
EER
(°F)
(Btu/Hr)
63
16,920
10.16
65
17,460
10.34
67
18,000
10.51
69
18,720
10.72
71
19,440
10.92
Indoor
Cooling
Wet Bulb Capacity
EER
(°F)
(Btu/Hr)
63
14,976
8.21
65
15,498
8.37
67
16,020
8.53
69
16,668
8.71
71
17,298
8.88
Indoor
Cooling
Wet Bulb Capacity
EER
(°F)
(Btu/Hr)
63
13,914
7.07
65
14,400
7.20
67
14,904
7.35
69
15,498
7.53
71
16,092
7.71
PUG/H18
(Indoor Air = 600 CFM)
75°F Outdoor Air Temperature
Net Sensible Cooling Capacity (Btu/Hr)
Total
Power
Indoor Dry Bulb (°F)
(Watts)
70
75
1,321
10,107
12,522
1,345
9,061
11,476
1,365
8,190
10,604
1,396
6,997
9,412
1,420
5,975
8,389
85°F Outdoor Air Temperature
Net Sensible Cooling Capacity (Btu/Hr)
Total
Power
Indoor Dry Bulb (°F)
(Watts)
70
75
1,509
9,833
12,247
1,531
8,790
11,204
1,554
7,732
10,147
1,585
6,732
9,146
1,617
5,706
8,121
95°F Outdoor Air Temperature
Net Sensible Cooling Capacity (Btu/Hr)
Total
Power
Indoor Dry Bulb (°F)
(Watts)
70
75
1,665
9,560
11,975
1,689
8,520
10,934
1,713
7,466
9,880
1,746
6,462
8,876
1,780
5,440
7,855
105°F Outdoor Air Temperature
Total
Net Sensible Cooling Capacity (Btu/Hr)
Power
Indoor Dry Bulb (°F)
(Watts)
70
75
1,824
8,797
11,211
1,852
7,776
10,191
1,879
6,743
9,157
1,913
5,739
8,154
1,948
4,714
7,128
115°F Outdoor Air Temperature
Net Sensible Cooling Capacity (Btu/Hr)
Total
Power
Indoor Dry Bulb (°F)
(Watts)
70
75
1,968
8,386
10,801
1,999
7,367
9,781
2,028
6,341
8,756
2,059
5,334
7,748
2,088
4,311
6,726
80
85
90
14,936
17,350
18,288
13,890
16,305
18,719
13,019
15,433
17,848
11,826
14,241
16,655
10,804
13,218
15,633
80
85
90
14,662
17,076
17,604
13,619
16,033
18,162
12,561
14,976
17,390
11,561
13,975
16,390
10,535
12,950
15,364
80
85
90
14,389
16,804
16,920
13,349
15,763
17,460
12,295
14,709
17,124
11,291
13,705
16,120
10,269
12,684
15,098
80
85
90
13,626
14,976
14,976
12,605
15,020
15,498
11,571
13,986
16,020
10,568
12,983
15,397
9,543
11,957
14,372
80
85
90
13,215
13,914
13,914
12,196
14,400
14,400
11,170
13,585
14,904
10,163
12,577
14,992
9,140
11,555
13,969
SP007-12
C
Pressures
(psig)
O
Suction
Disch.
74
175
O
77
177
80
182
L
83
186
87
194
N
Pressures
(psig)
G
Suction
Disch.
75
198
78
202
M
81
207
84
213
O
88
219
D
Pressures
E
(psig)
Suction
Disch.
77
225
79
230
82
236
86
242
90
249
Pressures
(psig)
Suction
Disch.
78
258
81
264
83
270
87
276
91
283
Pressures
(psig)
Suction
Disch.
80
292
83
298
85
303
89
310
94
317
I

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents