Samsung AS07A5MA Service Manual page 6

Split type air conditioner
Table of Contents

Advertisement

No.
Part
2
Electrical
Parts
(Main PCB)
Assembly Tray
3
Drain
Heat
4
Exchanger
Fan Motor and
5
Cross Fan
Procedure
1) Take all the connector of PCB
on the upper part. (Included Power cord)
2) Separate the outdoor unit connection
wire from the terminal block.
3) If you pull out the main PCB up, it will be
taken out.
1) Separate the drain hose from the
extension drain hose.
2) Pull tray drain out from the back body.
1) Loosen two ground screws at the
right side.
2) Separate the connection pipe.
3) Separate the holder pipe at the rear side.
4) Loosen three screws at the right and
left side.
5) Lift the heat exchanger up a little to push
the upper side to separate it from the
indoor unit.
1) Loosen two screws and separate the
motor holder.
2) Loosen the screw of fan motor.
(By use of M3 wrench)
3) Separate the fan motor from the fan.
4) Separate the fan from the left holder
bearing.
Remark