3.11.2 Totalizer Volume Readings by Meter Position

Meter volume totals are stored in statistical functions that are accessed using the remote control inter-
face. The totals for Side 1 are stored in function S05 and those for Side 2 are stored in function S06. The
value of the meter totals are stored in the sub-functions that take the format .M0, where M is the meter
number. Assigned values of M are shown in Table 3-2. For example, M=5 for the high feedstock iMeter
located on Side 1 of a remote series blender. For Side 2 of the same meter, M=1.
Note: There is no relationship between meter position and hose position. For example, in Table 3-1,
positions N=1 and N=5 are not the high feedstock of a remote series blender used in the exam-
ple above.
Meter electronic totalizers are read by entering the Maintenance Mode and accessing the correct func-
tion and associated sub-functions. Perform the following steps using the remote control. Bold type
denote remote control function; italicized type represents dispenser response.
Accessing the Meter Volume Totalizer Sub-function for Side 1
1. Press ENTER
PASS 1 (enter password)
2. Press ENTER
PASS 2 (enter password)
3. Press ENTER. The unit price display will show F
4. Press either UP or DOWN arrow to enter the statistics viewing mode. The unit price
display will show S— (indicating that a number needs to be selected)
5. Press 05 to access S05
6. Press ENTER. The unit price display will show S05 (indicating that the statistical
function has been accessed)
7. Press ENTER to access the sub-functions of S05. The unit price display will show
5.10 (note here that M=1)
Consecutive pressing of NEXT will allow access to the next sub-function, incrementing the value of M
by (.1). For example, to access S05.20, press NEXT. The unit price display will show 5.20. The value
of the meter volume totals is shown in a format such that the least significant six (6) digits of the data
value appear on the volume display, while higher order non-zero digits of the data value, if present,
appear on the money display. Leading zeros appear as blanks.
Values for M are given in Table 3-2 for the dispenser models shown.
Quick Exit
1. Press the CLEAR key until the unit price display window shows S - - .
2. Press ENTER three times. This causes the maintenance mode task to immediately terminate.