Manual 07500610 Model 3000-44 Model 3000-44 2(2x64) 2-wire Matrix 90400650 Page 1 peration Manual...
Page 2
Giga-tronics will, at its option, repair or replace products that are proven defective during the warranty period. This warranty DOES NOT cover damage resulting from improper use, nor workmanship other than Giga-tronics service.
San Ramon, California 94583 U.S.A. Type of Equipment: Model Series Number Switching Module 3000-44 Declaration of Conformity on file. Contact Giga-tronics at the following; Giga-tronics, Incorporated 4650 Norris Canyon Road San Ramon, California 94583 Telephone: 800.726.4442 (only within the United States) 925.328.4650...
Page 4
Manual 07500610 Model 3000-44 Record of Changes to This Manual Use the table below to maintain a permanent record of changes to this document. Corrected replacement pages are issued as Technical Publication Change Instructions (TPCI). When you are issued a TPCI, do the following: 1.
Manual 07500610 Model 3000-44 Chapter 1 Introduction 1.1 Safety and Manual Conventions This manual contains conventions regarding safety and equipment usage as described below. 1.1.1 Product Reference Throughout this manual, the term “Common Core Switching Platform, Series 8800” refers to all models of within the series, unless otherwise specified.
Manual 07500610 Model 3000-44 Chapter 2 Configuration Table Module 3000-44, (2x128) Standard Module PL90400650 Assy 90400650 Module 3000-44 Option 1, (2x128) Module, also known as Option “M”, has two additional inputs on DB PL90400650-101 Assy 90400650-101 Module 3000-44, 2(2x64) Module PL90400650-001...
Model 3000-44 Chapter 3 Functional Description 3.1 Introduction This User Guide provides a basic description of the 3000-44 2 x 128 Coaxial Switch Matrix module. Also included are installation and input connection procedures, programming information, service and maintenance information. 3.2 General Description This module is a dual wire 2 x 128 matrix switch.
Manual 07500610 Model 3000-44 Chapter 4 Block Diagram 2x16 2x16 2x16 2x16 Jumpers in for STD, -101 2x16 2x16 2x16 2x16 Detail 2x16 CH A (H) Shield Ch A (L) Jumpers in for -001,-101 CH B (H) Shield Ch B (L)
Chapter 5 Controls and Indicators The following controls and indicators are provided to select and display the functions of the ASCOR 3000-44 Module’s operating environment. 5.1 VXI Logical Address The Logical Address Switch is dual circular switches, D1 and D2 which are located at the rear of the module.
The following items are inside the module and can be reached by removing the side cover. 6.1 Fuse The ASCOR VXI 3000-44 uses a 10 Amp fuse in the +5 Volt line and is located on the Mother Board (MB) assembly.
The Model 3000-44 a VXI register based module. The switch paths are controlled via VXIMAX™ which is the 16/32 bit data controller. The Model 3000-44 can be programmed in 16 bit or 32 bit wide data. Through your VXI controller, write the data to the appropriate register as shown on the register map for the relay or relays in the register that is being closed.
Page 16
Manual 07500610 Model 3000-44 A16 Address Space Register Description Offset Value CFB5 hex C = Register based, A16/A24 FB5 = ASCOR Manufacturer ID 7F2C hex 7 = 10,000 hex space in the A24 Address space F2C = HV Discrete Driver/Receiver VXI Module number...