  • Page 1 Manual 07504353    Model 3000‐4353  Model 3000‐4353  32 SPST Switch Module  90401310          Page 1      peration Manual  ...
  • Page 2 Manual 07504353    Model 3000‐4353  All technical data and specifications in this publication are subject to change without prior notice and do  not represent a commitment on the part of Giga‐tronics, Incorporated.    © 2011 Giga‐tronics Incorporated. All rights reserved.  Printed in the U.S.A.        Warranty    3000 Switching  Modules Giga‐tronics  Series      are  warranted  against    three defective materials and workmanship for   year  from date of shipment,    or as detailed in the warranty section of this manual. Giga‐tronics will, at its  option,  repair  or  replace  products  that  are  proven  defective  during  the    warranty ...
  • Page 3: Regulatory Compliance Information

    EMC Directive and Low Voltage Directive EN61010-1 (1993) Electrical Safety EN61326-1 (1997) EMC – Emissions and Immunity Manufacturer’s Name: Manufacturer’s Address Giga-tronics, Incorporated 4650 Norris Canyon Road San Ramon, California 94583 U.S.A. Type of Equipment: Model Series Number Switching Module 3000-4353  ...
  • Page 4 Manual 07504353    Model 3000‐4353  Record of Changes to This Manual Use the table below to maintain a permanent record of changes to this document. Corrected replacement pages are issued as Technical Publication Change Instructions (TPCI). When you are issued a TPCI, do the following: 1.
  • Page 5: Revision History

    Manual 07504353    Model 3000‐4353  Revision History Revision Description of Change Chg Order # Approved By Initial Release Updated 6/02 Updated 2/08 Reformatted 3/12 Page 5      peration Manual  ...
  • Page 6: Table Of Contents

    Manual 07504353    Model 3000‐4353  Contents  Contents  ................................ 6  Chapter 1 Introduction .......................... 7  1.1 Safety and Manual Conventions  ...................... 7  1.1.1 Product Reference  ........................ 7  1.1.2 Personal Safety Alert ........................ 7  1.1.3 Equipment Safety Alert ....................... 7  1.1.4 Notes ............................ 7  1.1.5 Electrical Safety Precautions ....................... 7  Chapter 2 Configuration Table  ........................ 8  Chapter 3 Functional Description ......................... 9  3.1 Introduction  ............................ 9  3.2 General Description .......................... 9  Chapter 4 Front Panel .......................... 10  Chapter 5 Controls and Indicators ...................... 11  5.1 VXI Logical Address ........................... 11  5.2 LEDs .............................. 11  5.2.1 “BUS” LED  .......................... 11  5.2.2 “PWR” LED  .......................... 11  Chapter 6 Internal Settings ......................... 12  6.1 Fuse  .............................. 12  6.2 J105  .............................. 12  6.3 J107 ...
  • Page 7: Chapter 1 Introduction

    Manual 07504353    Model 3000‐4353  Chapter 1 Introduction  1.1 Safety and Manual Conventions  This manual contains conventions regarding safety and equipment usage as described below.  1.1.1 Product Reference  Throughout this manual, the term “Common Core Switching Platform, Series 8800” refers to all models  of within the series, unless otherwise specified.  1.1.2 Personal Safety Alert  WARNING: Indicates a hazardous situation which, if not avoided, could result in           WARNING  death or serious injury.    1.1.3 Equipment Safety Alert  CAUTION: Indicates a situation which can damage or adversely affect the product or  CAUTION  associated equipment.    1.1.4 Notes  Notes are denoted and used as follows:  NOTE: Highlights or amplifies an essential operating or maintenance procedure, practice, condition or  statement.    1.1.5 Electrical Safety Precautions  Any servicing instructions are for use by service‐trained personnel only.  To avoid personal injury, do not  perform any service unless you are qualified to do so.  For continued protections against fire hazard, replace the AC line fuse only with a fuse of the same  current rating and type.  Do not use repaired fuses or short circuited fuse holders.    Page 7      peration Manual  ...
  • Page 8: Chapter 2 Configuration Table

    Manual 07504353    Model 3000‐4353  Chapter 2 Configuration Table      TOP ASSEMBLY       PL 90401310  ASM 90401310       PL 85003950‐001  ASM 85003950‐001          SCH 85003950‐001  PL = PARTS LIST,  ASM = ASSEMBLY DRAWING,  SCH = SCHEMATIC.      Page 8      peration Manual  ...
  • Page 9: Chapter 3 Functional Description

    Manual 07504353    Model 3000‐4353  Chapter 3 Functional Description  3.1 Introduction  The ASCOR VXI 3000‐4353 consists of 32 Single Pole Single Throw (SPST) relays. This module can be used  as a direct interchange for the Tektronix VXI module VX4353. Each relay is independently controlled and  can be independently opened or closed under program control.  3.2 General Description  The 3000‐4353 is a direct hardware replacement for the Tektronix VX4353. The same front panel  connectors, the same signals come to the same pins, and the specifications are the same or better. No  special cables or adapter are necessary. ASCOR also provides a software driver which will run both the  VX4353 and the 3000‐4353.      Page 9      peration Manual  ...
  • Page 10: Chapter 4 Front Panel

    Manual 07504353    Model 3000‐4353  Chapter 4 Front Panel      Page 10      peration Manual  ...
  • Page 11: Chapter 5 Controls And Indicators

    Manual 07504353    Model 3000‐4353  Chapter 5 Controls and Indicators  The following controls and indicators are provided to select and display the functions of the ASCOR  3000‐4353 Module’s operating environment.  5.1 VXI Logical Address  The Logical Address Switch is dual circular switches, D1 and D2 which are located at the rear of the  module. The address can be set to any value between 1 and 255 (decimal) or 1 and FF (hexadecimal),  (address 0 is reserved for the resource manager). However, the Module fully supports Dynamic  Configuration as defined in Section F of the VXI specification, address 255 (FF) should be selected only if  the Resource Manager also supports Dynamic Configuration.    5.2 LEDs  The following LEDs are visible at the Module’s front panel to indicate the   status of the module’s operation:   5.2.1 “BUS” LED  This green color LED is normally off and will flash on when the module is addressed by the system.  5.2.2 “PWR” LED  This red color LED is normally on when the Module is Powered up.  Page 11      peration Manual  ...
  • Page 12: Chapter 6 Internal Settings

    Manual 07504353    Model 3000‐4353  Chapter 6 Internal Settings  The following items are inside the module and can be reached by removing the side cover.  6.1 Fuse  The ASCOR VXI 3000‐4353 uses a 5 Amp fuse in the +5 Volt line and a 5 A fuse in the +12 Volt line. If any  fuse opens, remove the fault before replacing the fuse to avoid any other damage.  6.2 VXI  Interrupt Level Selection  The VXIbus interrupt level is set with three bits in the “3Eh” register.   See the section on “A16 ADDRESS SPACE REGISTER DESCRIPTION”.  The interrupt level is factory set to “no interrupt”.        Page 12      peration Manual  ...
  • Page 13: Chapter 7 Specifications

    Manual 07504353    Model 3000‐4353  Chapter 7 Specifications    Configuration :          32 SPST individual relays.    Relay Type :          Aromat JQ1AE‐12V    Contact Ratings :        Switching Current (MAX) = 5A              Switching Voltage (MAX)  = 277VAC , 110VDC              Switching Power (MAX) = 1250 VA     Maximum operating Speed:   ...
  • Page 14 Manual 07504353    Model 3000‐4353    VXI Bus Radiated Emissions :      Complies with VXIbus Specification    VXI Bus Conducted Emissions :       Complies with VXIbus Specification.    Dimensions :           VXI C size ; 10.3in x 13.8in x 1.2in    Weight :          3  lbs.    Front Panel Connectors :       50 Position PC Mount                Tyco ( AMP ) 206971‐2        Page 14 ...
  • Page 15: Chapter 8 Register Map

    Manual 07504353    Model 3000‐4353  Chapter 8 Register Map  A16 Address Space Register Description Offset Value CFB5 hex C = Register based, A16/A24 FB5 = ASCOR Manufacturer ID 7F2C hex 7 = 10,000 hex space in the A24 Address space F2C = HV Discrete Driver/Receiver VXI Module number FFFC hex (typical after running Resource Manager) In order to reset the module: read this address, set bit 0 high, then set bit 0 low without altering the other bits.
  • Page 16 Manual 07504353    Model 3000‐4353  REGISTER = 8000h    REGISTER  REGISTER    8000h  8000h  RELAY  16 BIT  32 BIT  K1  0  0  K2  1  1  K3  2  2  K4  3  3  K5  4  4  K6  5  5  K7  6  6  K8  7  7  K9  8  8  K10  9 ...
  • Page 17: Chapter 9 Front Panel Pin List

    Manual 07504353    Model 3000‐4353  Chapter 9 Front Panel Pin List    RELAY  COMMON  NORMALLY OPEN  CONTACT  CONTACT  K1  P4‐2  P4‐1  K2  P4‐4  P4‐3  K3  P4‐6  P4‐5  K4  P4‐8  P4‐7  K5  P4‐10  P4‐9  K6  P4‐12  P4‐11  K7  P4‐14  P4‐13  K8  P4‐16  P4‐15  K9  P4‐19  P4‐18  K10  P4‐21  P4‐20  K11 ...