Burner Pressure Adjustment - Bosch 13P Installation & Operating Instructions Manual

Continuous flow gas water heater
Table of Contents

Advertisement

Commissioning

Burner Pressure Adjustment

With the gas supply turned off, loosen the captive screw in burner pressure test point
( Position A Figure 6 ) on the left hand side of the burner manifold.
Attach a "U" tube manometer , turn on the gas supply and light appliance. Open a hot water
tap to draw off more than 10 litres a minute ( in summer or when the inlet cold water is above
15°C it may be necessary to temporarily increase the maximum water flow to compensate for
the thermostat turning down the gas rate )
Adjust pressure if necessary at the pressure regulator fitted to the gas supply pipe. (Refer
data page 3)
A
Inlet Pressure
The gas supply pressure must be as stated on the appliance rating label, located bottom right
hand inside rear panel. The gas pressure at the inlet test point ( Position A Figure 7) will be
approx 100 pascals less than the supply pressure due to the pressure drop across regulator.
A
9 708 069 951 2
Figure 6
Figure 7
25/10/2011
Page6

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

16p