Scott Eagle Attack Operating And Maintenance Instructions Manual page 13

Scott eagle attack thermal imaging camera and charging system
Table of Contents

Advertisement

To charge a spare battery, proceed as follows:
1.
Inspect the three battery charging contacts on the charger assembly. The contacts must
be clean, straight, and undamaged.
2.
Inspect the three external battery terminals on the spare battery. The terminals must be
clean and undamaged.
3.
Hold the battery as shown in FIGURE 3, with the battery terminals aligned with the
charging contacts.
BATTERY FITS ONLY ONE WAY
FIGURE 3
4.
Hold the battery in place and secure with the hold down strap by stretching the strap over
the battery and fitting the pin in the strap under the two strap hooks.
The charger light will flash GREEN to indicate that the spare battery is charging. See
5.
FIGURE 4.
6.
When the battery is charged, the charger light will change to solid GREEN. A battery will
require approximately 2 hours for a FULL charge. After each use of the camera, the battery
should be recharged.
7.
To release the hold down strap, pull the strap end DOWN and AWAY from the base to
unhook the pin from the two strap hooks.
8.
If the light on the charger base FLASHES RED as soon as a EAGLE ATTACK Thermal
Imaging Camera is placed in the charger assembly, it indicates a defect in the battery.
REMOVE THE BATTERY FROM SERVICE AND DISPOSE OF ACCORDING TO
FEDERAL, STATE, AND LOCAL REGULATIONS.
REGULAR INSPECTION
Regularly inspect the EAGLE ATTACK CHARGING SYSTEM for worn or
damaged components.
– Verify that all fasteners and mounting hardware are present and tight.
– Check all battery contacts. The contacts must be clean and straight
– Check housing cradle and base for cracks or other damage
– Check the two (2) hold down straps or tears or cracks in the buckle which might
cause a failure of the strap.
If any loose, worn, or damaged components are found, remove the EAGLE ATTACK
CHARGING SYSTEM from service and tag for repair by authorized personnel.
REGULARLY INSPECT THE EAGLE ATTACK CHARGING SYSTEM FOR LOOSE,
WORN, OR DAMAGED COMPONENTS. IF ANY DAMAGE IS FOUND, REMOVE THE
UNIT FROM SERVICE AND TAG FOR REPAIR BY AUTHORIZED PERSONNEL.
Page 11 of 32
CHARGING
LIGHT
CAUTION
P/N 595224-01 Rev E 7/12
FIGURE 4

Advertisement

Table of Contents
loading

Table of Contents